Brivo OEC 715/785/865 Mobile C-Arm X-Ray Product
Page 4-11
CAUTION
Pulse Rate / Pulse
Press
“
Pulse
”
key
to enable pulsed imaging, press
“
Pulse Rate
”
key
to select pulse rate. Press
the key until the pulse rate you desire is selected. The illuminated LED indicates which pulse rate is selected.
Pulsed X-Rays can be used to reduce total radiation dose.
Using a pulsed fluoro mode can significantly reduce the dose received by the patient.
However, image quality may be degraded in pulsed fluoro modes.
Low Dose
Press the
“
Low Dose
”
key to select the Low Dose mode. The corresponding LED will illuminate to indicate
that Low Dose mode is selected.
Select Low Dose mode to reduce the exposure dose rate to the patient.
High Level Fluoro Mode& Digital Spot Mode Enable/Disable
This key is used to enable/disable HLF and Digital Spot mode. It
’
s only effective in Australia and other
countries when the laws and regulations require the use of this feature.
When pressing this key in these countries, the corresponding LED will illuminate and the High Level Fluoro
Mode, Digital Spot Mode could be enabled by pressing the right foot/handswitch. Press this key again to
disable the
High Level Fluoro Mode& Digital Spot Mode
. Make sure the LED lights before pressing the right
foot/handswitch to make exposure.
In the other countries, HLF and digital spot mode are always enabled, invalid key sound will be given when
pressing this key.
High Level Fluoro Mode and Digital Spot Mode are both High Dose Fluoro imaging which can
subject the patient and those working around the X-Ray field to a significantly larger dose of
radiation than they would receive during normal fluoro operation. To minimize X-Ray
exposure hazards, use High Level Fluoro imaging with discretion.
WARNING
Summary of Contents for Brivo OEC 715
Page 9: ...Chapter1 Introduction and Safety...
Page 34: ...Chapter2 System Overview...
Page 36: ...Brivo OEC 715 785 865 Mobile C Arm X Ray Product Page 2 3 2 2 C Arm Components...
Page 38: ...Brivo OEC 715 785 865 Mobile C Arm X Ray Product Page 2 5 2 3 Workstation Components...
Page 40: ...Chapter3 Mechanical Positioning...
Page 52: ...Chapter4 Start Up and Operating Control...
Page 77: ...Chapter5 Usual Operations...
Page 108: ...Chapter6 SpecialApplications...
Page 139: ...Chapter7 Radiographic Film...
Page 142: ...Chapter8 System Setup...
Page 149: ...System Setup Page 8 8 Click any mouse button to return to normal screen...
Page 150: ...Chapter9 Maintenance...
Page 160: ...Chapter10 Display Messages...
Page 162: ...Chapter11 Labels and Symbols...
Page 177: ...Labels and Symbols Page 11 16 42 12 15 29 40 15 13 10 18 39 31 27 24 23 37 38...
Page 179: ...Chapter12 Technical Reference...
Page 183: ...Brivo OEC 715 785 865 Mobile C Arm X Ray Product Page 12 5 Workstation Weight 170 10kg...
Page 206: ...Technical Reference Page 12 28 12 11 System Block...
Page 209: ......