- 47 -
November 12, 2016
Installation Manual for SX-4000 Standalone
Integrated Media Block™
with Enterprise Storage/Enterprise Storage Plus
12. AUTOMATION SETUP
12.3. Automation setup for eCNA devices
The SX-4000 supports the eCNA-10 automation system. Follow the steps below to configure an
eCNA device in the server automation interface.
1. Click
[Add]
on
[Devices]
and enter the name of the device. In this case, it is
[eCNA].
Set
the device type to
[eCNA_IO].
2. Click
[OK]
and set up the device parameters for the eCNA device.
Figure 43 eCNA automation device setup.
3. Enter the IP address of the eCNA device (see Figure 44).
4. The eCNA device has many cues available for automation. These cues can be enabled or
disabled by selecting them after clicking the
[Server events], [eCNA controls],
and
[eCNA
status]
buttons. All cues are disabled by default.
2
1