- 27 -
November 12, 2016
Installation Manual for SX-4000 Standalone
Integrated Media Block™
with Enterprise Storage/Enterprise Storage Plus
4. INSTALLING ENTERPRISE STORAGE/ ENTERPRISE SOTRAGE PLUS
RAID LED
Please see the table below for an explanation of RAID LED indicator:
Red
Buzzer
RAID LED
Flashing
Degrade/Broken
ON
Off
Normal
OFF
4.8.2. Warning Buzzer
Buzzer mute switch is located to the right of the RAID LED. Use a pen or similar shaped object to
turn the buzzer on or off.
WARNING:
This is not a reset switch for the buzzer. Once the button is toggled
to the “off” position
, the
buzzer will remain silent if any other hard disk fails. Please remember to toggle the switch on after replacing
any failed hard disks.
4.8.3. Hard Drive Failure
When a hard disk is showing an error, the hard disk must be removed.
When a replacement hard disk is inserted into the bay, it will be added into the RAID array
immediately; the RAID array will start rebuilding process automatically.
Note:
The hard disk must be a fresh drive. DO NOT reuse a hard disk from another Enterprise Storage/
Enterprise Storage Plus.