GCAN GCAN-212 User Manual Download Page 4

Vhandy Technology

GCAN-212 user manual

Integrated 2 CAN bus interfaces, using Phoenix terminal wiring mode;

CAN bus signals include: CAN_H, CAN_L, CAN_GND;

The CAN bus supports CAN2.0A and CAN2.0B frame formats, conforming

to the ISO/DIS 11898 specification;

CAN bus communication baud rate support 5kbps~1Mbps;

The CAN bus interface adopts electrical isolation, and the isolation voltage

of the isolation module: DC 1500V;

The highest sending and receiving data flow: 8000 fps and 14000 fps.

The time stamp accuracy of the message received by the CAN terminal can

reach 1us.

1.2.3 Ethernet properties

Use standard Ethernet interface, RJ45, support 10/100M self-adaption;

Support heartbeat and timeout disconnect function;

Working port, target IP and target port can be set;

Automatically restore connection resources after the network is

disconnected, and establish TCP connections reliably;

Compatible with SOCKET working methods (TCP Server, TCP Client,

UDP, etc.), the upper computer communication software complies with the
standard SOCKET rules.

1.3 Typical application

CAN bus network diagnosis and testing

Industrial Ethernet is connected to the CAN network

Electric power communication network

Industrial control equipment

High-speed, large data volume communication

Summary of Contents for GCAN-212

Page 1: ...GCAN 212 Industrial Ethernet CAN converter User manual Version V3 80 2120 10 20...

Page 2: ...4 4 3 Configure basic communication information 15 4 4 Configuration is complete 17 4 5 Save load configuration files 18 4 6 Upgrade GCAN 212 firmware kernel please use this function under guidance 18...

Page 3: ...12 has integrated the CAN interface electrical isolation protection module to prevent damage to the equipment due to instantaneous over current overvoltage and enhance the reliability of the system in...

Page 4: ...ived by the CAN terminal can reach 1us 1 2 3 Ethernet properties Use standard Ethernet interface RJ45 support 10 100M self adaption Support heartbeat and timeout disconnect function Working port targe...

Page 5: ...The overall size of the device length including terminal 118mm width 93mm height 22mm the schematic diagram is shown in Figure 2 1 and Figure 2 2 the user can design the installation and fixing holes...

Page 6: ...efinition and function The GCAN 212 module CANET II integrates one DC9 24V power interface two standard CAN bus interfaces and one Ethernet interface The power interface is led out by a 3 PIN plug in...

Page 7: ...3PIN plug in terminals green which can be used to connect 2 CAN bus networks or devices with CAN bus interface The interface position and interface definition are shown in Figure 2 4 and Table 2 2 Sho...

Page 8: ...CAN 212 is powered on find the reset button in the device as shown in the figure above press the button for about 5 6 seconds wait until the SYS indicator CAN1 CAN2 indicator and LAN indicator flash i...

Page 9: ...4 TCP IP Win7 properties Click Modify in the IP Address column and enter the IP address of the same network segment as GCAN 212 as shown in the figure 3 2 You can complete the operation of adding and...

Page 10: ...ccessful the client will continue to try to establish a connection with the TCP server according to the set connection conditions After establishing a TCP connection with the TCP server two way data c...

Page 11: ...h CAN bus GCAN 212 is connected to CAN bus by connecting CAN_H to CAN_H and CAN_L to CAN_L to establish communication The CAN bus network adopts a linear topology and the two farthest terminals of the...

Page 12: ...cator to indicate Bus status The specific indication functions of these 5 indicators are shown in Table 3 2 When these 5 indicators are in different states the status of GCAN 212 is shown in Table 3 2...

Page 13: ...mmunication failure occurs the red indicator light will light up Indicator light State Indicating status PWR Bright The power supply is normal not bright Power supply failure SYS not bright Device ini...

Page 14: ...device The system default IP 192 168 1 10 the default CAN bus baud rate is 250k Refer to 3 1 1 for details about restoring factory settings 4 2 GCAN 212 connection When configuring the GCAN 212 device...

Page 15: ...3 Configure basic communication information After the connection is successful click UpLoad to upload the parameters in the device to the computer When users modifying parameters click the parameter t...

Page 16: ...4 3 2 CAN bus parameter setting Click CAN1 CAN2 Info to enter the CAN bus parameter setting interface TCP Port Set CAN bus communication port CAN Baud Set the CAN bus communication baud rate detailed...

Page 17: ...50 k bit s 10 500 k bit s 3 40 k bit s 11 400 k bit s 4 20 k bit s 12 250 k bit s 5 13 3 k bit s 1491123 200 k bit s 6 10 k bit s 13 125 k bit s 7 5 k bit s 14 Table 4 1 Comparison table of baud rate...

Page 18: ...can be saved to the computer convenient for direct call next time You can click SaveAs to save the configuration information to a local file This configuration file can also be opened through the soft...

Page 19: ...e IP address of GCAN 212 in the IP field and the port number of the CAN channel in the Port field and click Connect to connect to the device At this time if there is data on the CAN bus the software w...

Page 20: ...that you have configured GCAN 212 If you use a PC to connect to the GCAN 212 device you can enter the cmd command prompt of the computer after the GCAN 212 device is powered on press windows R enter c...

Page 21: ...test In the configuration software set the TCP Mode of the CAN1 channel to 1 that is GCAN 212 is in TCP Server mode and the CAN baud rate CAN Baud is 5 which is 250k Enter the network debugging assist...

Page 22: ...the configuration software set the TCP Mode of the CAN1 channel to 2 that is GCAN 212 is in TCP Client mode the remote IP address Remote IP is the IP address of the PC and the remote port number Remot...

Page 23: ...DP mode the remote IP address Remote IP is the IP address of the PC and the remote port number Remote Port is the port number of the IP address The default value is 8001 Enter the network debugging as...

Page 24: ...ing assistant will display a status message for example AA 00 FF 00 31 31 39 31 32 31 34 36 33 the fifth byte of this heartbeat message indicates the channel number 31 indicates the CAN1 channel and 3...

Page 25: ...y GCAN 212 user manual interval is 2 seconds This message can help you detect whether the connection status of the TCP port is normal When the CAN channel transmits data normally the status message wi...

Page 26: ...y GCAN 212 user manual 7 Modifying Parameters Online The GCAN 212 supports online modification of configuration parameters over Ethernet If you need to use this function contact Guangchen technical su...

Page 27: ...his code or integrate this function into the existing software system The secondary development of GCAN 212 equipment does not require the use of dynamic library files All the upper computer software...

Page 28: ...rt CAN2 0A B CAN baud rate 5Kbit s 1Mbit s Electrical isolation DC1500V CAN terminal resistance Has been integrated select whether to enable or not through the dial switch Power supply Supply voltage...

Page 29: ...to an Ethernet switch HUB 4 What is the highest data conversion rate of GCAN 212 The single CAN channel of GCAN 212 supports CAN bus data conversion up to 8000 fps The frame mentioned here refers to t...

Page 30: ...ser manual the device it will try to prevent the system from entering the standby or sleep state so as to ensure the normal operation of the system When using GCAN 212 please disable the standby and s...

Page 31: ...atement carefully Once used it is deemed to be an endorsement and acceptance of the entire content of this statement Please strictly abide by the manual product description and related laws regulation...

Page 32: ...frame 1 is extended frame 0 is standard frame RTR Identification bit of remote frame and data frame 1 is remote frame 0 is data frame UDP The identification bits of UDP and TCP 1 is UDP 0 is TCP set...

Page 33: ...h 33h 44h 55h 66h 77h 88h 28h 00h 00h 01h 23h 11h 22h 33h 44h 55h 66h 77h 88h Please note In the process of mutual conversion between CAN bus data and Ethernet data the CAN frame must be 13 bytes in t...

Page 34: ...s and Service Shenyang Vhandy Technology Co Ltd Address ROOM 401 BOLOCK D11 SISP HUNNAN DISTRICT SHENYANG CITY LIAONING PROVINCE CHINA E mail info gcanbus com Tel Whatsapp 86 13644001762 Skype live sy...