Vhandy Technology
GCAN-212 user manual
frame filters can be set.
'TCP Mode'——Set TCP working mode.
'Remote IP'——Set the IP address of the target host.
'Remote Port'——Set the port number of the target host.
Note: "Remote IP" and "Remote Port" are only valid in TCP Client mode and
UDP mode.
Baud rate
Corresponding
number
Baud rate
Corresponding
number
1 M bit/s
0
100 k bit/s
8
800 k bit/s
1
80 k bit/s
9
666 k bit/s
2
50 k bit/s
10
500 k bit/s
3
40 k bit/s
11
400 k bit/s
4
20 k bit/s
12
250 k bit/s
5
13.3 k bit/s
1491123
200 k bit/s
6
10 k bit/s
13
125 k bit/s
7
5 k bit/s
14
Table 4.1 Comparison table of baud rate and corresponding numbers
Note: If you want to use a custom baud rate, please contact us by any means
(please refer to the last page for contact information)
4.4 Configuration is complete
When the user modifies a certain parameter, this part will turn red in the
software. After the user completes the configuration, click "Download
Parameters" to download the configuration information to the GCAN-212
Flash.