Please note: After the configuration is successful, power on the GCAN-212
device again. When using the network debugging assistant, you need to check
'Hexadecimal Display' and 'Hexadecimal Send'.
6.4 UDP mode communication test
In the configuration software, set the TCP Mode of the CAN channel to 3, that
is, GCAN-212 is the UDP mode; the remote IP address (Remote IP) is the IP
address of the PC, and the remote port number (Remote Port) is the port
number of the IP address. The default value is 8001. Enter the network
debugging assistant, select the protocol type as UDP; the local host address is
the PC IP address, and the local host port is the remote port number set in the
configuration software.
Please note: After the configuration is successful, power on the GCAN-212
device again. When using the network debugging assistant, you need to check
'Hexadecimal Display' and 'Hexadecimal Send'.