___________________________________________________Chapter 5 – Odor Control Section, Page 5-5
Odor Control – Maintenance (Cont.)
Caution - Exhaust fan must be off before opening the odor control media access door.
Refilling the Modules is a relatively simple task not requiring any special tools. Follow steps 1-15:
1.
Turn off exhaust fan.
2.
Open Media Access Door.
3.
Carefully slide out the Modules.
4.
Set the Module on end so the securing screw is on top.
5.
Remove the securing screw and slide the cover plate off (Refer to Figure 5-5-1).
6.
Empty the old media into a container for disposal.
7.
Place the filling jig over opening.
8.
Pour the media into the Module.
9.
To eliminate voids, shake or vibrate the Module to ensure that the media settles.
10.
Continue adding media until Module is full.
11.
Caution: Do not overfill as it may cause the sides to bulge.
12.
Replace cover plate and install securing screw.
13.
Optional - some dusting may occur on initial startup of the unit. To minimize
this, vacuum or blow out the Modules (Refer to Figure 5-5-2).
14.
Slide the Modules back into the rack being cautious that the airflow label is matching the airflow of
the unit (Refer to Figure 5-5-3).
15.
Replace the Odor Media Access Door.
Figure 5-5-1
Figure 5-5-2
Figure 5-5-3