CHAPTER 4: Installing Components
www.gateway.com
48
Replacing or adding a processor
Warning
Processors and heat sinks may be hot if
the computer has been running. Before
replacing a processor or heat sink, allow
them to cool for several minutes.
Caution
A heat sink must be installed on the
processor. Installing a processor without
a heatsink could damage the processor.
The server is compatible with as many as two Intel® Xeon DP (Dual Core) 5100
Series processors. The server automatically detects the processors each time
you turn it on. Whenever you install new processors, you should first install the
most current version of the BIOS. For instructions, see
.
Important
You must have a processor in the
Processor 1 socket, or your server will not
start.
If you are upgrading your server from one
processor to two, you may need to
reconfigure your operating system so it
can recognize the additional processor.
For instructions, see your operating
system’s documentation.
To replace a processor:
1
Install the most current BIOS version. For instructions, see
2
Follow the instructions in
“Preventing static electricity discharge” on
. Make sure that you turn off the server, then unplug the power
cord(s) and all other cables connected to the server.
Important
If you install two processors onto the
system board, the processors must be the
same speed, revision, core voltage, and
bus speed.
3
Follow the instructions in
“Opening the server case” on page 31
4
Push down, then pull out and up on the two heat sink retention levers (1)
and move them out of the way.
Caution
The heat sink has Thermal Interface
Material (TIM) on the bottom. Be careful
not to damage this material when you
remove the heat sink from the processor.
If removing the heat sink also pulls the
processor out of the processor socket, the
processor could be damaged.
5
Remove the heat sink from the processor. If the heatsink sticks to the
processor, rotate the heatsink slightly to loosen it.
Summary of Contents for E-9425R
Page 1: ...USER GUIDE Gateway E 9425R Server ...
Page 2: ......
Page 6: ...Contents www gateway com iv ...
Page 16: ...CHAPTER 1 Checking Out Your Gateway Server www gateway com 10 ...
Page 26: ...CHAPTER 2 Setting Up Your Server www gateway com 20 ...
Page 68: ...CHAPTER 4 Installing Components www gateway com 62 ...
Page 105: ...APPENDIX B 99 BIOSSettings ...
Page 116: ...APPENDIX B BIOS Settings www gateway com 110 ...
Page 117: ...APPENDIX C 111 Safety Regulatory and Legal Information ...
Page 127: ......
Page 128: ...A MAN E 9425R USR GDE R0 10 06 ...