Replacing system fans
www.gateway.com
47
4
Lift the fan cage and fans (1) out of the server.
5
Push the fan board lock (2) toward the back of the server case to release
the fan board.
6
Push the fan board toward the fan board lock to disengage it from the
locking tabs (3), then lift the fan board out of the server case.
7
Insert the replacement fan board into the server case, aligning the locking
slots in the board with the locking tabs in the case.
8
Push the fan board away from the fan board lock, then move the lock into
position to hold the fan board in place.
Important
Make sure that the arrows on top of the
fans indicating airflow point to the back
of the chassis.
9
Place the system fan cage and fans onto the fan board, making sure to
engage the fan cage with the locking tabs on the chassis.
10
Connect the 6-pin fan tach cables from the fans to the fan tach connectors
on the fan board.
11