CHAPTER 8: Failover, Performance, and Additional Functions
www.gateway.com
100
How StorView server failover works
If you are using the host-based version of StorView, two or more host servers
must be directly connected to the RAID Storage Solution enclosure and each
host must have a copy of StorView installed with a Global Access license. If you
are using the embedded version of StorView, you must have dual controllers
installed (duplex topology), each with Embedded StorView installed.
At startup, each StorView server creates a device list of all the attached storage
systems. Then it sends the list out on the network as a device list packet. The
other StorView servers on the network respond with their device list packets.
Since the StorView servers are attached to the same storage solution, they have
the same or similar devices in their device list packet. The identical devices in
each device list packet are flagged. After analysis, the StorView server with the
lowest serial number or address takes control of those devices. The other
StorView Server indicates on its interface that another StorView server is
monitoring the storage solution.
During normal operations, the StorView server(s) send
check-in
packets every
10 seconds. If three consecutive check-in packets for a specific StorView Server
are not received, its devices are flagged and the StorView server attached to that
storage solution with the lowest serial number or address takes control of those
devices.
StorView performance optimization
You can adjust some parameters on the host HBA and operating system to
increase the performance of StorView. They are the HBA Execution Throttle
setting and the operating system's Scatter/Gather registry setting.
Execution throttle
To improve general I/O performance by allowing more commands on the fibre
bus or the SCSI bus, we recommend changing your host bus adapter’s execution
throttle parameter to 256. See your host HBA documentation for more
information.
Scatter/gather
(Microsoft Windows Only) To increase general I/O performance by allowing
larger data transfers, we recommend editing the
MaximumSGList
parameter
in the registry. The recommended hexadecimal value is
ff
. The path is:
HKEY_LOCAL_MACHINE/System/CurrentControlSet/Services
/<name of HBA driver>/Parameters/Device/
See your Microsoft Windows operating system documentation for more
information on editing the registry and your host HBA adapter documentation.
Summary of Contents for E-842R
Page 1: ...USER GUIDE Gateway E 842R StorView Storage Management Application ...
Page 2: ......
Page 7: ...CHAPTER 1 1 Introduction Overview Inter server communication License manager ...
Page 10: ...Chapter 1 Introduction www gateway com 4 ...
Page 11: ...CHAPTER 2 5 Installation Setup for Microsoft Windows platforms Setup for Linux platforms ...
Page 44: ...CHAPTER 3 Getting Started www gateway com 38 ...
Page 76: ...CHAPTER 5 SAN LUN Mapping www gateway com 70 ...
Page 77: ...CHAPTER 6 71 ControllerInformation Controller environmentals Controller advanced settings ...
Page 86: ...CHAPTER 6 Controller Information www gateway com 80 ...
Page 104: ...CHAPTER 7 Managing the Storage Solution www gateway com 98 ...
Page 110: ...CHAPTER 8 Failover Performance and Additional Functions www gateway com 104 ...
Page 120: ...APPENDIX A Troubleshooting and Support www gateway com 114 ...
Page 144: ...APPENDIX B Event Logs www gateway com 138 ...
Page 152: ...APPENDIX C Statistics www gateway com 146 ...
Page 158: ...APPENDIX D Optimizing RAID 5 Write Performance www gateway com 152 ...
Page 162: ...Index www gateway com 156 ...
Page 163: ......
Page 164: ...A MAN E 842R SW USR GDE R0 09 06 ...