EN
25
Installation Instructions
FUSE 2AT
SW2
SW1
SW3
GLB mode ON=Master: OFF=Slave
(figure 24)
DIP Switch settings for RFID reader on individual GLB Wallbox
To activate RFID reader on a GLB Wallbox that is stand-alone (not connected with other GLB
Wallboxes), it is important to set the GLB-Wallbox as master (set switch SW1 (DIP 5) to ‘ON).
To verify that the master wallbox is defined as master, ensure the switch SW1 (DIP 5) is set to ‘ON’.
Note: It is only possible to have one Master GLB in a system when connecting GLB Wallboxes with
the datalink bus.
If several GLB-Wallboxes are connected in group, all GLB slaves must be connected to the
data link bus and be energized before the RFID function is activated. GLB slaves that
are not plugged in or powered will not receive RFID command and remain open for
charging and the RFID function is disabled.
RFID settings, see section Web interface in this manual.