2 SAFETY
2.1
SAFETY DEFINITIONS
WARNING
Risk of personal injury or death.
CAUTION
Risk of damage to the product or the adjacent area.
NOTE
Information that is necessary in a given situation.
2.2
SAFETY INSTRUCTIONS FOR
INSTALLATION
WARNING
Read and understand the safety warnings below before
installation of the product.
WARNING
Do not use a damaged charging station or a charging
station that has a red blinking (slow 0,5 Hz) indication
light. If a defect is found, speak to the owner of the
charging station. The owner can be found in the GARO
Connect app. Only use charging cables with no visible
defects and intended for charging the relevant EV.
Follow all instructions for the relevant EV.
•
Do not remove the screws from the sealed assembly
points on the rear side of the charging unit.
Removed screws or broken sealing will void the
warranty.
•
All installation must be carried out by an authorized
installer and comply with local country installation
regulations. If any questions, please contact your
local electrical authority.
•
Refer to local standards and regulations not to
exceed charging current limitations.
•
Ventilation signal from EV is not supported. This
means that test of “State D” is not possible.
•
Adapters for charging connectors are not allowed
to be used.
•
Cord extension sets for charging cable is not
allowed to be used.
•
Do not use private power generators as a power
source for charging.
•
Incorrect installation and testing of the charging
station could potentially damage either the EV and/
or the charging station itself.
•
Do not operate the charging station in temperatures
outside its operating range. Refer to
station technical data, page 95
•
Avoid high voltage insulation testing on connected
charging stations. If insulation testing is necessary,
first remove the charging unit from the installation
bracket.
•
If the charging station is set up without any internet
connectivity, it will allow charging up to the
maximum current defined for the charging unit. The
maximum current can be up to 32 A. Default at
delivery, the maximum setting is 16 A. This means
that an unconfigured charging station will function
without any internet connection, up to 16 A.
•
Do not use the product if any parts are damaged.
•
Do not connect an EV if the indication light is
blinking a slowly in red (0,5 Hz).
Version: 1.3
9
Summary of Contents for ENTITY PRO
Page 4: ......
Page 8: ......
Page 10: ......
Page 18: ......
Page 48: ...100A LI 1 LI 2 48 Version 1 3 Installation...
Page 100: ......
Page 101: ...EU DECLARATION OF CONFORMITY Version 1 3 101 EU Declaration of conformity...
Page 102: ...102 Version 1 3 EU Declaration of conformity...