3. Dismantle the control cable and the wires inside the
control cable.
NOTE
The recommended conductor strip length is 10 mm.
4. If the cable has strained conductors, use cable
ferrules to the conductors.
5. Install the cables to the connector.
a. If the cables have solid conductors or ferrules,
push them into the connector.
b. If the cables have soft conductors, use a flat
screwdriver to open the spring mechanism in the
connector before you push the cable in.
NOTE
If wires need to be disconnected, use a flat screwdriver
to push the orange button to open the terminal.
4.12.11 TO CHANGE THE POSITION OF THE TYPE
2 OUTLET OR FIXED CABLE
As default, the Type 2 outlet or the fixed cable is located
on the right side of the charging unit. The position of the
Type 2 outlet or fixed cable can be changed.
1. Turn the charging unit to the rear side.
2. Slide the Type 2 outlet or fixed cable (A) and the
protective cover/cable holder (B) out of the
charging unit.
10 mm
Max 1.5 mm²
OPEN
36
Version: 1.3
Summary of Contents for ENTITY PRO
Page 4: ......
Page 8: ......
Page 10: ......
Page 18: ......
Page 48: ...100A LI 1 LI 2 48 Version 1 3 Installation...
Page 100: ......
Page 101: ...EU DECLARATION OF CONFORMITY Version 1 3 101 EU Declaration of conformity...
Page 102: ...102 Version 1 3 EU Declaration of conformity...