background image

4x PoE Smart MPPT Charger

Model: SM-SW-40

SolarSwitch

Summary of Contents for SunMax SM-SW-40

Page 1: ...4x PoE Smart MPPT Charger Model SM SW 40 SolarSwitch...

Page 2: ...ments Flathead screwdriver Ferrule crimper or pliers 18 14 AWG wires for battery connectors 24V or 2x12V SLA AGM or Gel lead battery Solar panel with H4 connectors 10 60V open circuit voltage Shielded...

Page 3: ...ttings Press and hold the Reset button for 16 seconds if The device does not respond to a factory reset The web interface is unreachable There doesn t appear to be any other noticeable activity Batter...

Page 4: ...he factory default password for this device The password can be found on the sticker located underneath the SolarSwitch Rack Mounting 1 Attach the 1U rackmount bracket included to either side of the S...

Page 5: ...attery terminal block 4 Crimp a ferrule on one end of the wire 5 Insert the crimped wire into the appropriate slot on the four pin connector Using a flathead screwdriver secure the wire to the connect...

Page 6: ...nector is fully occupied with all four wires 7 Connect wires and NTC Thermistor to batteries Note The battery will not be charged without connecting the NTC Thermistor 24VDC NTC Thermistor NTC Thermis...

Page 7: ...8 Attach the NTC and battery cable using the four pin connector 9 Attach the PV panel cables...

Page 8: ...address automatically from a DHCP server Use the Ubiquiti Device Discovery Tool to determine its IP address If there is no DHCP server on the LAN the SolarSwitch will fall back to the following IP add...

Page 9: ...er ubnt in the Username field 3 Enter the password in the Password field the password can be found on the sticker located under the port cover 4 Click Set Device Location to set the location for your...

Page 10: ...Enabling PoE To enable PoE on the SolarSwitch 1 Click Output on the Settings screen 2 Click the toggle button from OFF to ON for each port you want to enable...

Page 11: ...en Circuit Voltage 60V PV Maximum Current 10A PV Power Control MPPT Output Interfaces 24VDC Passive PoE Pins 4 5 7 8 24VDC Terminal Block Output Voltage Battery Voltage Limited to 24V Surge Protection...

Page 12: ...ttery Charging Profile Maximum Charging Current Absorption Charge Voltage Float Voltage 95 of Absorption Charge Voltage of Target Charging Voltage Battery Temperature C Absorption Charge Voltage Depen...

Page 13: ...red with respect to voltage frequency and current requirements indicated on the manufacturer s label Connection to a different power source than those specified may result in improper operation damage...

Page 14: ...if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operations of this equipment in a residential area is likely to cause harmful...

Page 15: ...pour l exposition aux rayonnements dans un environnement non contr l Lors de l installation et de la mise en fonctionnement de l quipement assurez vous qu il y ait une distance minimale de 20 cm entre...

Page 16: ...ronische Ger te ber die daf r zust ndigen und von der Regierung oder rtlichen Beh rden dazu bestimmten Sammelstellen zu entsorgen Ordnungsgem es Entsorgen und Recyceln tr gt dazu bei potentielle negat...

Page 17: ...s locaux le service de traitement des d chets ou l endroit o vous avez achet le produit Italiano La direttiva europea 2012 19 UE richiede che le apparecchiature contrassegnate con questo simbolo sul p...

Page 18: ...0 device is in compliance with the essential requirements and other relevant provisions of Directives 2014 53 EU 2014 30 EU 2014 35 EU The full text of the EU declaration of conformity is available at...

Page 19: ...Visas ES atitikties deklaracijos tekstas prieinamas iuo interneto adresu ui com compliance Malti Maltese Hawnhekk UBIQUITI tiddikjara li dan il mezz SM SW 40 huwa konformi mar rekwi iti essenzjali u...

Page 20: ...jem spletnem naslovu ui com compliance Espa ol Spanish Por medio de la presente UBIQUITI declara que este dispositivo SM SW 40 cumple con los requisitos esenciales y cualesquiera otras disposiciones a...

Page 21: ...UNMS are trademarks or registered trademarks of Ubiquiti Inc in the United States and in other countries All other trademarks are the property of their respective owners Support help ui com Community...

Reviews: