REED SWITCH OPERATION
(continued)
FRONT
REED
REAR
REED
LOWER��
LIMIT
UPPER�
LIMIT
CLOSED
OPEN
OPEN
OPEN
Platen in the Up Position – Switches are in NORMAL state.
OPEN
OPEN
OPEN
OPEN
Platen movement command has been initiated.
Upper Limit switch as OPENED.
OPEN
CLOSED
OPEN
OPEN
Platen has moved to the DOWN position.
Lower Limit switch has CLOSED.
OPEN
OPEN
OPEN
OPEN
Platen has raised up to PREHEAT GAP SETTING of .450.
Lower Limit Switch OPENS.
AUTO�CALIBRATION�BEGINS�AFTER�GRILL�REACHES�TEMPERATURE�AND�COUNTDOWN�TIMER�EXPIRES
OPEN
CLOSED
OPEN
OPEN
Auto calibration begins. Lower Limit Switch CLOSES
OPEN
CLOSED
CLOSED
OPEN
Platen continues to move down. Rear Reed Switch CLOSES.
OPEN
CLOSED
CLOSED
CLOSED
Platen continues to move down. Front Reed Switch CLOSES.
OPEN
CLOSED
CLOSED
OPEN
Linear Actuator reverses polarity. Platen Raises.
Front Reed Switch OPENS.
OPEN
CLOSED
OPEN
OPEN
Platen continues to rise. Rear Reed Switch OPENS.
OPEN
OPEN
OPEN
OPEN
Platen continues to ruse. Lower limit switch opens.
CLOSED
OPEN
OPEN
OPEN
Platen continues to ruse. Upper Limit switch OPENS.
Movement stops.