background image

Part # 4519762 (12/07)

Page 9

Shutdown Instructions

To shut down fryer for a short period, turn automatic gas 
valve knob to the “PILOT” position.

For complete shutdown, turn automatic gas valve knob 
clockwise to “PILOT” position, depress the knob, turn slightly 
clockwise, release, and continue to turn clockwise to “OFF”.

Calibration Instructions

1.  Field calibration is seldom necessary and should not 

be attempted unless experience with cooking results 
definitely proves that the control is not maintaining the 
temperature to which the dial is set.

2.  Suspend thermometer or thermocouple in the middle 

of the fry tank, approximately 2” (51 mm) below the 
shortening level.

3.  Allow burner to cycle at least four times.

4.  When the burner just cycles off after the fourth cycle, 

compare reading of the thermometer or thermocouple 
with thermostat setting.

5.  If the two do not agree, ± 10°F (5°C), loosen the two set 

screws on the thermostat knob.

6.  Set the pointer at the temperature indicated by the 

thermometer.

7.  Tighten the set screw firmly.

8.  Ensure the back surface of the knob is spaced away from 

the dial plate at least the thickness of a dime.

NOTE: Do not turn adjusting shaft more than two turns in 
either direction or permanent damage can result. This action 
will void the Standard Fenwal thermostat warranty.

Griddles

IMPORTANT: The flue must be installed prior to start-up.

Lighting Instructions And 
Pilot Burner Adjustment 

Each griddle burner is equipped with a pilot.

For the HI-LO valve operated model, the pilot adjusting valve 
pilot burner is located on the manifold to the left of each 
griddle valve. Open the pilot valve with a screwdriver and 
light the pilot with a match.

ADJUSTMENTS Continued

For the griddle equipped with thermostats the pilot and the 
main burner are controlled by the ON-OFF valve.

MAKE SURE 

THE THERMOSTAT IN ON OFF POSITION

. Turn on the main 

valve and light the pilot with a match. The pilot adjusting 
screw is located at the bottom of the thermostat.

Pilots flames must be 3/4 inch (19mm) long 

Burner Operation

The burner will light automatically from the pilot. Turn the 
valve to full “ON” position. Once the flame has ignited, adjust 
the valve to the desired setting.

Hi-Lo Valve Adjustment

Griddles equipped with Hi-Lo valves require a low flame 
setting. To adjust, proceed as follows:

1.  Burner must be cold.

2.  Be sure pilot flames are lit, and adjusted.

3.  Turn dial to “LO” position, then remove dial.

4.  With a screwdriver, turn the small adjusting screw inside 

the valve stem and adjust to obtain the low cooking 
temperature desired, maintaining a stable flame covering 
the entire burner (minimum 3/16 inch (5 mm) long 
flame).

5.  Replace dial and turn to “OFF” position.

Calibration Instructions

1.  Use a test instrument with a special disc type 

thermocouple or a reliable surface type pyrometer. Note: 
a drop of oil on the face of the disc will provide better 
contact with the plate.

2

Set all griddle thermostats to 350°F (177°C). In order 
to allow the griddle temperature to stabilize, the 
thermostats must be allowed to cycle twice before taking 
a test reading.

3. Check the griddle temperature when the thermostat 

just cycles “OFF” by placing the thermocouple firmly on 
the griddle surface directly above the sensing bulb of 
the thermostat. The reading should be between 335°F 
(168°C) and 365°F (185°C). If the reading is outside of 
these limits, calibrate as follows:

4.  Carefully remove the dial, not disturbing the shaft 

position.

Summary of Contents for GD Series

Page 1: ...Mississauga Ontario L4W 1X4 CANADA Phone 905 624 0260 Fax 905 624 5669 Enodis UK LTD Swallowfield Way Hayes Middlesex UB3 1DQ ENGLAND Telephone 081 561 0433 Fax 081 848 0041 Part 4519762 03 06 2005 Ga...

Page 2: ...d expose you to airborne particles of glass wool ceramic fibers Inhalation of airborne particles of glass wool ceramic fibers is known to the state of california to cause cancer Operation of this prod...

Page 3: ...tion 8 Fryers 8 Before Operating the Fryer 8 Pilot Burner Adjustment 8 To Operate Main Burner 8 Shutdown Instructions 9 Calibration Instructions 9 Griddles 9 Lighting Instructions And Pilot Burner Adj...

Page 4: ...late affixed to the unit contains this information We suggest installation maintenance and repairs should be performed by your local authorized service agency listed in your information manual pamphle...

Page 5: ...uipped with griddle thermostats the thermostat bulb must be inserted in the groove between the plate and the bulb shield assembly This can be accomplished with the griddle front raised and supported b...

Page 6: ...en the unit is installed to ensure that the unit gas pressure is the same as specified on the rating plate If necessary pressure adjustments can be made at the pressure regulator supplied on each unit...

Page 7: ...achine screws through the 7 32 5 mm diameter holes in stand into nutserts in the bottom of GD Series units Ventilation Counter equipment must be installed in a location in which the facilities for ven...

Page 8: ...is necessary to clean the fry tank before filling with frying compound Use detergent or other cleaning agents with hot water Thoroughly rinse and dry fry tank 2 BEFORE LIGHTING THE PILOT fill the fry...

Page 9: ...with a screwdriver and light the pilot with a match ADJUSTMENTS Continued For the griddle equipped with thermostats the pilot and the main burner are controlled by the ON OFF valve MAKE SURE THE THER...

Page 10: ...the pilot Turn the valve to the full ON position Once the flame has ignited adjust the valve to the desired setting HI LO Valve Adjustment Broilers are equipped with HI LO valves which require a low f...

Page 11: ...the pilot is established push the tap in again and turn it anti clockwise to the full flame position to light the main burner 5 For low flame or simmer push the tap in and turn it anti clockwise to t...

Page 12: ...valve and wait five minutes to let the gas build up escape 8 Only once the pilot flame has been established should you turn on the burner control When the burner control is on it allows gas flow to t...

Page 13: ...ainless scouring pads DO NOT USE ORDINARY STEEL WOOL Heat tint can be removed by a vigorous scouring in the direction of the polish lines using Scotch Brite scouring pads or a Stainless scouring pad i...

Page 14: ...Part 4519762 12 07 Page 14...

Page 15: ...liser de produits abrasifs Acier inoxydable Les salissures normales peuvent tre limin es avec une solution de d tergent ou de savon appliqu e avec un chiff on INSTRUCTIONS D ENTRETIEN suite Pour limin...

Page 16: ...fl amme de la veilleuse par le trou d observation dans le panneau avant en acier inoxydable 7 Si la veilleuse ne s allume pas rapidement et que vous sentez une odeur de gaz fermez le robinet principa...

Page 17: ...es entailles Les temp ratures le plus souvent utilis es vont de 300 F 149 C 350 F 177 C Apr s une cuisson la plaque du gril va se d colorer Cela est normal et n aff ectera pas les r sultats de cuisson...

Page 18: ...i cacit et une stabilit maximales utiliser des ustensiles fond plat et les placer au centre de la t te de br leur Allumage De La Plaque Chauff ante De Type Ouvert Pour allumer les br leurs de plaque o...

Page 19: ...er la temp rature Nota Chaque 1 4 de tour de la vis modifi e la temp rature d environ 25 F 14 C 6 Remettre en place le cadran du thermostat et r p ter les tapes 1 3 pour v rifi er que le r glage est c...

Page 20: ...le comparez l indication du thermom tre ou thermocouple au r glage du thermostat 5 S ils ne correspondent pas 10 F 5 C desserrer les deux vis de blocage du bouton du thermostat 6 R gler le pointeur la...

Page 21: ...tion extr me ON Une fois la fl amme allum e r gler le robinet selon le r glage souhait Friteuses Avant D utiliser La Friteuse 1 Avant son d part de l usine la friteuse a t test e et son thermostat tal...

Page 22: ...ans la section intitul e Installation des plaques d union 5 Fixer la derni re unit au socle de plan de travail l aide de vis m taux 8 32 et de rondelles plates Ins rer les vis m taux 8 32 travers les...

Page 23: ...nal tique Si n cessaire les r glages de pression peuvent tre eff ectu s au r gulateur de pression fourni sur chaque appareil 4 Faire v rifi er la pression du gaz par un technicien qualifi afi n de s a...

Page 24: ...appareils dot s de thermostats de gril le bulbe thermostatique doit tre ins r dans la rainure entre la plaque et l ensemble de protection du bulbe Pour cela il est n cessaire de soulever l avant du gr...

Page 25: ...fi x e l appareil contient ces renseignements Nous sugg rons de faire faire l installation l entretien et les r parations par une agence de service agr e locale fi gurant dans la manuel d informations...

Page 26: ...iliser La Friteuse 8 R glage Des Veilleuses 8 Pour Utiliser Le Br leur Principal 9 Instructions D extinction 9 Instructions D talonnage 9 Grils 9 Instructions D allumage Et R glage Des Veilleuses 9 Ut...

Page 27: ...res de laine de verre fibres c ramiques L inhalation de ces particules de laine de verre ou de fibres c ramiques est reconnue par l tat de Californie comme causant le cancer L utilisation de ce produi...

Page 28: ...DA T l phone 905 624 0260 T l copieur 905 624 5669 Enodis UK LTD Swallowfi eld Way Hayes Middlesex UB3 1DQ ANGLETERRE T l phone 081 561 0433 T l copieur 081 848 0041 Pi ce n 4519762 12 07 2005 Garland...

Reviews: