32
When other devices are under Low
Battery Status, the Green LED flashes
every 2 seconds
602 - Periodic test report
When CTC-1052 reports Periodic test
call to monitoring Center.
606 - Follow-On Function
When CTC-1052 receives kiss-off from
Monitoring Center for opening Speech
channel.
611 - Global test
When CTC-1052 reports Global Test to
Monitoring Center.
641 - Mobility
When CTC-1052 makes Mobility Timer
Expired reporting.
<NOTE>
This event code will be sent with a fixed
zone number of
071
661 - Nurse arrived/nurse finished his
work
When the nurse arrives within the
preset time and presses the green
reset button. The event qualifier Q is
“1”.
When the nurse finishes treatment for
the caller and presses the green reset
button again. The event qualifier Q is
“3”.
If the nurse has pressed the green
reset button once in help arrived mode
but did not press the green reset button
again within the preset time to end help
arrived mode, CTC-1052 will send this
event code with the event qualifier Q
“1” every 15 minutes for four times.
662 - Nurse needs help
When the nurse needs more help and
presses the red help button to call for
assistance.
663 - Helped arrived mode canceled
When the green reset button is pressed
twice in help arrived mode to cancel
help arrived mode.
5.2. Tunstall Event Code
D#1011 - Panel AC Restored/ Help
Arrived
When AC power is restored to CTC-
1052.
When CTC-1052 makes Help Arrived
reporting.
D#1012 - Global test & Periodic test
report
When CTC-1052 reports Global Test to
monitoring Center.
When CTC-1052 reports Periodic test
call to monitoring Center.
D#1013 - Sensor Supervisory Failure
When CTC-1052 is unable to receive
the signal transmitted from the Wrist
Transmitter for a pre-set period by
Command #49.
D#1014 - Device Low Battery
When devices are under Low Battery
Status, the Green LED flashes every 2
seconds.
D#1015 – Mobility/Inactivity
When CTC-1052 makes Mobility Timer
Expired reporting.
If no sudden movement within 10
seconds after fall detection, an
inactivity code will be sent to Central
Monitoring Station.
D#1016 - Personal emergency or Fall
emergency
When Wrist Transmitter / Emergency
Pendant (WTR), or Fall Sensor is
pressed.
When a fall sensor is triggered
D#1017 - Panel emergency
When the Red HELP Panel button is
pressed.
When Water sensor is triggered.
D#1018 - Smoke emergency
When Smoke Detector (SD) is
triggered or Smoke Detector’s test
button is pressed.
When Carbon Monoxide Detector (CO)
is triggered or Carbon Monoxide
Summary of Contents for CTC-1052
Page 1: ...E1 August 25 2017...