19
If no signal is received within 20
sec, CTC-1052 will emit a long beep
and
automatically
returns
to
Programming mode.
Step 3:
CTC-1052 will emit 2 beeps to
indicate that Silent Pendant is learnt-
in successfully.
Adding a Pendant for a second time
is prohibited unless it is removed
from the system first.
If
one long beep
is emitted instead
of 2 beeps, it indicates:
The device has already been
learnt-in.
Another device has been learnt-in
before.
<NOTE>
When CTC-1052 received the alarm
signal from the Silent Pendant, it will
not emit any warning beeps during
Reporting and Guard time period.
Command 94
Learn-In Device
<NOTE>
This command is not available in
Remote Programming Mode.
Up to 17 devices can be learnt into CTC-
1052 by using Command #94.
The available devices that can be learnt-in
Command #94 are:
PIR Sensor ----- PIR
Smoke Detector ---- SD
Carbon Monoxide ---- CO
Fixed Panic Button ---- PB
Wrist Transmitter ---- WTR
Pendant Transmitter ---- WTR
Water Sensor ---- WS
Fall Sensor
Step 1:
Enter
94
+
#
on the phone set, then
a short beep will be heard via the
phone set. (If no command is dialed,
CTC-1052 will exit Programming
mode automatically and return to
idle mode).
Step 2:
Press the learn button on the device
within 20 seconds.
Learning can only be completed
within the signal reception range of
CTC-1052.
If no signal is received within 20
sec, CTC-1052 will emit a long beep
and
automatically
returns
to
Programming mode.
Step 3:
CTC-1052 will emit 2 beeps to
indicate the device is learnt-in
successfully.
Adding a Pendant for a second time
is prohibited unless it is removed
from the system first.
If
one long beep
is emitted instead
of 2 beeps, it indicates:
The device has already been
learnt-in.
When an 8
th
device is attempted
to learn-in.
Step 4:
Repeat steps 1-3 until all devices
are learnt-in.
<NOTE>
Adding a device for a second time is
prohibited unless it is removed from the
system first.
If the
Follow on
or
Call Back
function
is set by
Command 38
, the Control
Panel will follow the preset parameter
to open the two-way communication.
Summary of Contents for CTC-1052
Page 1: ...E1 August 25 2017...