25
to set CMS IP Address(es) (SMS
Commands: TCIP1 and TCIP2).
Port Number:
Central Monitoring Station
server port number. Please refer to
5.5.
CTC-1052 SMS Remote Programming
Table
on how to set Port Number(s) (SMS
Commands: PORT1 and PORT2).
GPRS/IP Account Number:
There are 2
account numbers available for GPRS/IP
reporting. Please refer to
5.5. CTC-1052
SMS Remote Programming Table
on how
to set GPRS/IP Account Number(s) (SMS
Commands: IPAC1 and IPAC2).
To disable GPRS Reporting Method:
by
removing the IP address, GPRS reporting
becomes ineffective. Proceed to SMS
Remote Programming and send in this
format:
“
PROG 1111 TCIP1:
”
Where:
PROG
= SMS Keyword
1111
= Access Code
TCIP1
= SMS command for IP Address (no
input value means deletion of characters)
If Command 33 is enabled, the panel will
enter Help Arrived Mode after GPRS
reporting. Please refer to
Help Arrived
Mode
below.
4.2.2. Digital Reporting Method
If Digital Reporting Method is selected, after
dialing, the Control Panel will report digital
event codes according to the format of the
report (set by Commands 20-24).
If SMS CID reporting is selected, the event
codes will be sent in the form of a SMS
message to the reporting destination.
Post-Digital-Alarm Operation
After a successful digital report, CTC-1052
will then follow the choice of Command
#38, to enter
Follow-On and/or Call-Back
mode.
Call-Back Operation
If Command #38 is set as Call-Back
(1)
or
Follow-On & Call-Back
(2)
after alarm
reporting, it will then wait 5 minutes for
Monitoring Center Personnel to call-back
after reporting.
<NOTE>
Call-back option is disabled by default.
If Auto-Answer Number is programmed:
If the Monitoring Center calls back within
the 5-minute Call-Back period using an
auto-answer number, the Control Panel will
pick up the call and instantly open up a two-
way communication with the caller.
If at least one Auto-Answer Number is
programmed, the Control Panel will only
answer calls from the Auto-Answer
Numbers.
If
no
Auto-Answer
Number
is
programmed:
If the Monitoring Center calls back within
the 5-minute Call-Back period, the Control
Panel will automatically answer the call
after the 1
st
-2
nd
rings and wait for proper
Access Code (default is 1111) and the (#)
key entry within 12 seconds.
Upon receiving the correct Access Code
and the (#) key, CTC-1052 will then open a
Full-Duplex Communication to allow the
caller to communicate directly.
During a call-back communication
,
Monitoring center can use the following
DTMF command to control the Control
Panel:
Enter
(1)
to
TALK ONLY
Enter
(2)
to open
TWO-WAY VOICE
COMMUNICATION
Enter
(3)
to
LISTEN-IN ONLY
End a Call: enter (
9
) or (
0
) to
HANG
UP or
put the handset back into the
base cradle.
Enter
(7)
to Speaker Volume Control
and then press
(6)
or
(4)
to increase
or decrease levels of speaker volume
in the “Two-Way” communication
mode(not in
TALK ONLY
mode).
Enter
(8)
to Microphone Sensitivity
Control and then press
(6)
or
(4)
to
increase or decrease levels of
microphone sensitivity in the “Two-
Way” communication mode.
Summary of Contents for CTC-1052
Page 1: ...E1 August 25 2017...