24
4.2. Alarm Activation
When an alarm is triggered, CTC-1052 will
enter the Guard Time Delay period (see
Command 42). Both Red LED and
Red
Help Button
backlight will turn on.
During the Guard Time period,
pressing the
Green Reset Button
on
CTC-1052 will stop alarm reporting
and return to Idle Mode.
If the Guard Time Delay is set as
00
,
CTC-1052 will dial immediately.
An alarm report can be canceled anytime
by pressing the
Green Reset Button
on
CTC-1052.
Call Progress Tone
Once Guard Time Delay expires, CTC-1052
will
summon
help
based
on
the
programmed reporting method. If Call
Progress Tone is set as On, dailing tones
will be heard once the CTC-1052 goes off-
hook.
Guard Time Delay
Guard Time Delay time is a time period
programmed to delay alarm reporting (by
command #42). If a false alarm is raised,
the user can cancel the alarm before the
Control Panel starts reporting.
Emergency alarms activated by Smoke
Detectors
(SD),
Carbon
Monoxide
Detectors (CO) and Water Sensors (WS)
do not have Guard Time Delay and will be
reported immediately. CTC-1052 will play
voice prompt “Fire Alarm,” “Carbon
Monoxide Alarm,” “Water Leak Alarm” to
inform the user of the alarm at hand.
During this time period, a continuous series
of beeps (1 beep every 0.5 second) will be
emitted and voice prompt “Emergency call
was pressed” to alert the user(s).
<NOTE>
The Guard Time Delay triggered from a
fall detection (of a Fall Sensor) has its
own
timer
(programmed
using
Command 66). The CTC-1052 will play
voice prompt “A fall has been
detected,” to notify the user; and “Fall
detection has restored, cancelling help
call” voice prompt, when fall detection
has been cancelled.
Confirmation Beeps
After Guard Time expires, CTC-1052 will
summon help based on the programmed
reporting method. The Control Panel will
start emitting a continuous confirmation
beeping sound (about 1 beep every
second) and voice prompt “Emergency call
in progress” to indicate that the call is in
progress.
The Control Panel will emit Confirmation
beeps and voice prompt during the
following situations:
After the Control Panel dials out to
summon help and until handshake (for
Digital Reporting Method).
After the Control Panel dials out to
summon help and until the call is
answered (for Speech Reporting
Method).
When the first reporting failed, and the
Control Panel retries.
The
Control
Panel
stops
emitting
confirmation beeps once the first reporting
succeeded and it is in the process of back-
up reporting.
4.2.1. GPRS Reporting Method
Please program GPRS Report settings via
SMS Remote Programming Commands for
GPRS Reporting Methods. Below are the
settings required for GPRS reporting:
Access Point Name (APN):
the name of
an access point for GPRS. Please inquire
your SIM card service provider for your
APN.
User Name:
offered by your SIM card
service provider.
Please inquire your
service provider for your GPRS username.
If no username is required, you may skip
this step.
Password:
offered by your SIM card
service provider.
Please inquire your
service provider for your GPRS password.
If no Password is required, you may skip
this step.
IP Address:
Central Monitoring Station
server IP. Please refer to
5.5. CTC-1052
SMS Remote Programming Table
on how