4.2. Alarm Activation 

  When an alarm is triggered, CTC-1052 will 

enter  the  Guard  Time  Delay  period  (see 
Command  42).  Both  Red  LED  and 

Red 

Help Button

 backlight will turn on. 

 

During  the  Guard  Time  period,  
pressing the 

Green  Reset  Button

 on 

CTC-1052  will  stop  alarm  reporting 
and return to Idle Mode. 

 

If  the  Guard  Time  Delay  is  set  as 

00

,  

CTC-1052 will dial immediately. 

  An  alarm  report  can  be  canceled  anytime 

by  pressing  the 

Green  Reset  Button

  on 

CTC-1052. 

 

Call Progress Tone   

  Once Guard Time Delay expires, CTC-1052 

will 

summon 

help 

based 

on 

the 

programmed  reporting  method.  If  Call 
Progress  Tone  is  set  as  On,  dailing  tones 
will be heard once the CTC-1052 goes off-
hook. 

 

Guard Time Delay 

 

Guard  Time  Delay  time  is  a  time  period 
programmed  to  delay  alarm  reporting  (by 
command  #42).  If  a  false  alarm  is  raised, 
the  user  can  cancel  the  alarm  before  the 
Control Panel starts reporting. 

 

Emergency  alarms  activated  by  Smoke 
Detectors 

(SD), 

Carbon 

Monoxide 

Detectors  (CO)  and  Water  Sensors  (WS) 
do not have Guard Time Delay and will be 
reported  immediately.  CTC-1052  will  play 
voice  prompt  “Fire  Alarm,”  “Carbon 
Monoxide  Alarm,”  “Water  Leak  Alarm”  to 
inform the user of the alarm at hand. 

 

During this time period, a continuous series 
of beeps (1 beep every 0.5 second) will be 
emitted  and  voice  prompt  “Emergency  call 
was pressed” to alert the user(s). 

<NOTE> 

 

The Guard Time Delay triggered from a 
fall  detection  (of  a  Fall  Sensor)  has  its 
own 

timer 

(programmed 

using 

Command 66). The CTC-1052 will play 
voice  prompt  “A  fall  has  been 
detected,”  to  notify  the  user;  and  “Fall 
detection  has  restored,  cancelling  help 

call”  voice  prompt,  when  fall  detection 
has been cancelled.  

Confirmation Beeps 

  After  Guard  Time  expires,  CTC-1052  will 

summon  help  based  on  the  programmed 
reporting  method.  The  Control  Panel  will 
start  emitting  a  continuous  confirmation 
beeping  sound  (about  1  beep  every 
second) and voice prompt “Emergency call 
in  progress”  to  indicate  that  the  call  is  in 
progress. 

  The  Control  Panel  will  emit  Confirmation 

beeps  and  voice  prompt  during  the 
following situations: 

 

After  the  Control  Panel  dials  out  to 
summon help and until handshake (for 
Digital Reporting Method). 

 

After  the  Control  Panel  dials  out  to 
summon  help  and  until  the  call  is 
answered  (for  Speech  Reporting 
Method). 

 

When the first reporting failed, and the 
Control Panel retries. 

  The 

Control 

Panel 

stops 

emitting 

confirmation  beeps  once  the  first  reporting 
succeeded and it is in the process of back-
up reporting. 

 

4.2.1. GPRS Reporting Method 

  Please  program  GPRS  Report  settings  via 

SMS Remote Programming Commands for 
GPRS  Reporting  Methods.  Below  are  the 
settings required for GPRS reporting: 

 

Access  Point  Name  (APN):

  the  name  of 

an  access  point  for  GPRS.  Please  inquire 
your  SIM  card  service  provider  for  your 
APN. 

 

User  Name:

  offered  by  your  SIM  card 

service  provider.

 

Please  inquire  your 

service  provider  for  your  GPRS  username. 
If  no  username  is  required,  you  may  skip 
this step. 

 

Password:

  offered  by  your  SIM  card 

service  provider.

 

Please  inquire  your 

service  provider  for  your  GPRS  password. 
If  no  Password  is  required,  you  may  skip 
this step. 

 

IP  Address:

  Central  Monitoring  Station 

server  IP.  Please  refer  to 

5.5. CTC-1052 

SMS Remote Programming Table

 on how 

Summary of Contents for CTC-1052

Page 1: ...E1 August 25 2017...

Page 2: ..._______________ 5 3 1 4 SMS Remote Programming __________________________________________ 6 3 2 Programming Your 1052 ______________________________________________ 6 3 3 SMS Remote Programming_______...

Page 3: ...n Idle Mode ___________________________________________________________________ 30 4 4 Global Test_________________________________________________________ 30 4 5 Factory Reset________________________...

Page 4: ...c disable mobility setting 4 RED HELP BUTTON with backlight Back lit disigned for easy access at night Backlight illuminates when off hook Backlight flashes during the waiting period until help arrive...

Page 5: ...y power to CTC 1052 and at the same time recharge the battery It takes approximately 72 hours to fully charge the battery The battery can be manually disconnected by the battery switch located at the...

Page 6: ...vices such as mobile phones cordless phone or wireless computer network Wi Fi devices Important When drilling into a wall ensure there are no hidden cables or pipes Mounting the Control Panel The Cont...

Page 7: ...sed the CTC 1052 will emit one beep sound initially and then will emit a double beep on the 6th second 2 Release the Green Reset Button at the voice prompt Release the Green button Ready to learn sens...

Page 8: ...eparetely that features a built in keypad and LCD display to help you to program the medical alarm panels effeciently and conveniently It also features Once for All Uploading which allows you program...

Page 9: ...ia SMS commands Please refer to section 3 3 SMS Remote Programming for usage 3 2 Programming Your 1052 How to enter Commands Please make sure CTC 1052 is in Programming Mode RED LED flashes continuous...

Page 10: ...ly NOTE When entering the phone number entering means a 3 second pause e g Switchboard system extension etc For example the phone number is 21111111 and extension number is 255 Enter 21111111 255 Up t...

Page 11: ...mbers 2 GPRS IP NOTE The Tel number selected in Command 7 will not be used for alarm and or status reporting even if it is selected in command 5 and or 6 When multiple Tel numbers are selected CTC 105...

Page 12: ...eeps via the telephone handset to alert the call recipient the remaining time of 20 10 secs Speech Reporting made under Silent Mode set by Command 35 will automatically be switched to Listen in but ca...

Page 13: ...F CTC 1052 will return to idle mode when Alarm Reporting is completed Function Selection Result 0 OFF Disable 1 ON Enable Factory Default is set as 0 OFF NOTE If the Green Reset Button is not pressed...

Page 14: ...efault is as 0 Follow On When this function is programmed as 0 after a successful reporting to the Monitoring Center CTC 1052 will automatically enter the Follow On mode as specified by Command 45 Whe...

Page 15: ...cannot auto answer the call by ring count If you want to do Remote programming please follow the Remote Programming method described in 3 System Confguration 3 1 Entering Programming Mode 3 1 3 Remote...

Page 16: ...tion Result 00 DISABLE 01 1HR 02 2HR 36 36HR Factory Default is set as 00 DISABLE NOTE The Mobility Timer counting down can be reset by 1 Pressing the Green Reset Button on CTC 1052 or 2 Movement dete...

Page 17: ...way Full duplex Communication mode for 1 10 minutes set by Command 46 that gives the user the ability to speak directly with the Monitoring Center Personnel NOTE If either Scancom or Tunstall reporti...

Page 18: ...61 Check SIM Card PIN Code This option is used to check SIM card PIN Code Function Selection Result 0 OFF Disable 1 ON Enable Factory default is set as 0 OFF NOTE If this function is disabled the syst...

Page 19: ...ion for configuration Example if you want to raise the speaker volume to level 5 in the Two Way mode please enter 2 5 NOTE The volume value in the Listen In or Talk Only mode is adjusted for the best...

Page 20: ...r followed by If the number is successfully programmed the telephone handset will emit one short beep If the number is unable to be programmed the Control Panel will emit one long beep Auto Answer Num...

Page 21: ...Any DTMF Function Selection Result 0 Any DTMF 1 OFF HOOK Command 78 Mobility Time Out Warning When Mobility Time expires and no reset signal is received CTC 1052 will emit a long beep every 5 minutes...

Page 22: ...ant Transmitter WTR Water Sensor WS Fall Sensor Step 1 Enter 94 on the phone set then a short beep will be heard via the phone set If no command is dialed CTC 1052 will exit Programming mode automatic...

Page 23: ...and returns to idle mode 3 3 SMS Remote Programming NOTE Prior to procced please be reminded to change the language setting of your mobile phone to English Step 1 Use your handset and go into the SMS...

Page 24: ...anel can program up to 2 Auto Answer Numbers If a user calls the Control Panel using an auto answer number the Control Panel will pick up the call and instantly open up a two way communication with th...

Page 25: ...s from Immediately after powering up CTC 1052 Exit Programming Mode After the pre set Timer expires CTC 1052 will emit a long beep and voice prompt reminder Inactivity timer expiring please reset at e...

Page 26: ...e number Step 3 Once the test message is received you can then check the phone number format shown in the received message EXAMPLE With the phone number 0987654321 the format should either INCLUDE or...

Page 27: ...as been detected to notify the user and Fall detection has restored cancelling help call voice prompt when fall detection has been cancelled Confirmation Beeps After Guard Time expires CTC 1052 will s...

Page 28: ...Back 1 or Follow On Call Back 2 after alarm reporting it will then wait 5 minutes for Monitoring Center Personnel to call back after reporting NOTE Call back option is disabled by default If Auto Ans...

Page 29: ...he Monitoring Center can remotely control CTC 1052 by the DTMF commands below Enter 7 to Speaker Volume Control and then press 6 or 4 to increase or decrease the levels of speaker volume in the Two Wa...

Page 30: ...red CTC 1052 will end the report retry no more and return to idle mode When help has arrived the Green Reset Button can be pressed twice quickly to send a Help Arrived Mode Canceled report to the Moni...

Page 31: ...y Control and then press 6 or 4 to increase or decrease levels of microphone sensitivity in the Two Way communication mode NOTE Speech Reporting made under Silent Mode or using a Silent Device will au...

Page 32: ...ere will only be a maximum of 15 retries regardless of whether the reports were successful or not 4 3 Walk Test Range Test Walk Test or Range test is a test to check whether learned in devices are wit...

Page 33: ...al Test Step 1 Press the Green Reset Button once Step 2 Within 5 seconds press Pendant button Step 3 CTC 1052 will emit a short beep and report to Monitoring Center 4 5 Factory Reset CTC 1052 will cle...

Page 34: ...hen Carbon Monoxide Detector CO is triggered When the Test Button of Carbon Monoxide Detector CO is pressed 301 Panel AC Failure When AC power fails for more than 10 sec the Green LED flashes every se...

Page 35: ...assistance 663 Helped arrived mode canceled When the green reset button is pressed twice in help arrived mode to cancel help arrived mode 5 2 Tunstall Event Code D 1011 Panel AC Restored Help Arrived...

Page 36: ...ion an inactivity code will be sent to Central Monitoring Station 555556558 Panel Low battery Panel Battery Disconnection When CTC 1052 is under Low Battery status the Green LED flashes every 2 second...

Page 37: ...his device complies with Part 15 of the FCC Rules Operation is subject to the following conditions 1 This device may not cause harmful interference 2 This device must accept any interference received...

Page 38: ...ct ID 21 Bi 0 Contact ID 1 Scancom 2 Tunstall 3 Speech 4 SMS CID Tel Number 1 Bi Contact ID 22 Bi 0 Contact ID 1 Scancom 2 Tunstall 3 Speech 4 SMS CID Tel Number 2 Bi Contact ID 23 Bi 0 Contact ID 1 S...

Page 39: ...ay Speak volume 1 digit 1 5 level Bi Two way mode 3 64 Bi Set Microphone Sensitivity Note Mic sensitivity 1 digit 1 5 level Only can be adjusted in the two way mode Bi Two way Mode 3 66 Bi Guard time...

Page 40: ...t number 1 ACNT1 PROG 1111 ACNT1 1234 To set change the 4 6 8 digit account number for Telephone number 1 Null to clear account number for Telephone number 1 No account number 12 Account number 2 ACNT...

Page 41: ...delay time for a compatible sensor except Fall Sensor 00 Instant 01 99 1 99 seconds 00 instant reporting 10 10 seconds 43 Periodic test call TESTC PROG 1111 TESTC 0 To set the periodic test call 0 Off...

Page 42: ...PLA PROG 1111 REPLA 886 0 To replace the Country Code with 0 886 Country Code No country code IP address TCIP1 PROG 1111 TCIP1 192 168 1 110 To set change the IP address for the Monitoring Station Inp...

Page 43: ...PRS server confiramtion purpose only They do not change the IP address nor the port number settings 2 GPRS functions can only be programed via SMS messages and the commands MUST be sent in this sequen...

Page 44: ...41 message sent by the cell phone 3 SMS remote programming command can only be sent in the standby mode 4 The SMS command is successfully set after getting a confirmation message...

Page 45: ...is connected Consult the dealer or an experienced radio TV technician for help FCC Caution To assure continued compliance any changes or modifications not expressly approved by the party responsible...

Page 46: ...me si le brouillage est susceptible d en compromettre le fonctionnement IC Radiation Exposure Statement This equipment complies with IC RSS 102 radiation exposure limit set forth for an uncontrolled...

Reviews: