Check battery.
#1070
MEASUREMENT NOT
CORRECT
Sensor value on probe
device after repeated
positioning >0.01 or
<-0.01.
Carry out reset.
Clean the surface or
measurement sphere.
Tighten measurement
sphere.
Trained specialist for
mechanical work
#1085
REFERENCE LENGTH
DOES NOT MATCH
TOOL LIST
L_POS: Difference
between length spe-
cification in the tool
memory and the input
mask.
Carry out reset.
Correct the tool length
in the input mask.
Trained specialist for
mechanical work
#1095
DISTANCE FROM TOOL
TO BREAKAGE MONIT-
ORING TO LARGE
Tool start position
>8 mm in front of
breakage monitoring.
Carry out reset.
Correct the start posi-
tion of Z-.
Trained specialist for
mechanical work
#1105
TOOL BREAKAGE
Tool broken.
Carry out reset.
Replace tool.
Trained specialist for
mechanical work
#1115
LENGTH NOT PLAUS-
IBLE OR SWARF NEST
Cause could be due to
swarf or the tool has
been pulled out of the
holder.
Remove swarf.
Check whether the tool
has been pulled out of
the holder.
Trained specialist for
mechanical work
#1125
FEED RATE FACTOR /
MEASUREMENT RATE
TOO HIGH
Measurement feed rate
in input mask too high
Maximum feed rate
factor = 3 / =>
1500 mm/min.
Carry out reset.
Reduce measurement
feed rate.
Trained specialist for
mechanical work
#1135
TOOL LENGTH NOT
PLAUSIBLE
L_BREAK: length read
out of tool memory not
plausible.
Carry out reset.
Check tool length in
controller.
Check difference
between tool tip and
tool setting dimension
D1 in input mask yy. D1
length is checked.
Check correctness of
position determination
of the XC with L_POS.
Trained specialist for
mechanical work
#1145
INCORRECT MODE IN
INPUT MASK
L_LENGTH: Value in in-
put mask is not 0 or 1.
Carry out reset.
Change mode in input
mask:
0 = only measure tool
length.
1 = overwrite tool
length.
Trained specialist for
mechanical work
#1155
BREAKAGE MONITOR-
ING ALREADY ACTIV-
ATED
The tool that is to be
monitored for breakage
already touches the
TOOL CHECK upon pro-
gram start.
Carry out reset.
Correct the start posi-
tion of Z+.
Trained specialist for
mechanical work
#1160
BATTERY VOLTAGE
TOO LOW
Battery flat.
Carry out reset.
Change the battery.
Trained specialist for
mechanical work