; M19 / M20 SPINDLE ORIENTATION
9
Q1913 = 19
10
;=================================
11
CALL PGM TNC:\X_CONTROL\L_LENGTH.H
12
END PGM BSP_L_LENGTH MM
Back to Heidenhain automatic operation [
7.4.4.
Auxiliary cycle L_START
Probe cycle
Function
Note
Program code
L_START
XControl switches to standby
mode after 10 minutes without
measurement. Reactivation of
wireless connection is automatic
upon call-up of a probe cycle,
but takes approx. 15 seconds.
Auxiliary cycle L_START can be
used to manually reactivate the
wireless connection, in order to
reduce non-productive times.
L_START
Example/program code: CALL PGM TNC:\X_CONTROL\L_START_XC1.H ;
T1234
Change tool.
⁝
NC program
⁝
Tool positioning 5 mm above the XControl.
Back to Heidenhain automatic operation [
7.4.5.
Auxiliary cycle L_RESET
Probe cycle
Function
Note
Program code
L_RESET
After 100 probe processes, the
wireless connection is deactiv-
ated. The reactivation of the
wireless connection is automatic
upon call-up of a probe cycle,
but takes approx. 15 seconds.
Through call-up of the auxiliary
cycle, the counter of the meas-
urements is reset and the wire-
less connection is maintained.
L_RESET
Example/program code: CALL PGM TNC:\X_CONTROL\L_RESET_XC.H ;
Back to Heidenhain automatic operation [
8.
Error messages
Error code
Fault
Possible cause
Action
Performed by
#1010
WIRELESS SIGNAL
MISSING
Wireless connection
between the stick and
the probe device can-
not be established.
Carry out reset.
Check whether measur-
ing device is within
wireless range.
Reconnect USB stick.
Trained specialist for
mechanical work