#1170
SENSOR VALUE NOT
PLAUSIBLE
Sensor value smaller
than 2.1 or greater than
4.5 mm.
Carry out reset.
Remove and reinsert
the battery.
Trained specialist for
mechanical work
#1180
USB REBOOT FAILED =
RECONNECT USB STICK
WIRELESS CONNECT
has not registered des-
pite NC command.
Carry out reset.
Reconnect USB stick.
Trained specialist for
mechanical work
#1195
LOW BATTERY X_CON-
TROL_1
Low battery.
Change the battery.
Trained specialist for
mechanical work
#2005
LOW BATTERY X_CON-
TROL_2
Low battery.
Change the battery.
Trained specialist for
mechanical work
9.
Cleaning
Clean with a cloth or compressed air.
Do not use any corrosive cleaning agent.
10. Maintenance
The XControl is maintenance-free.
11. Storage
Store in an enclosed dry room.
Do not store close to corrosive or aggressive chemical substances, solvents, moisture or dirt.
Protect against direct sunlight.
Store at temperatures b15° C and +35 °C.
Relative atmospheric humidity max. 60%
12. Disposal
Comply with the national and regional environmental protection and disposal regulations for
correct disposal or recycling. Segregate items into metals, non-metals, composite materials and
consumables and dispose of them responsibly. Re-use is preferable to disposal.
Do not dispose of batteries in domestic waste.
Use return and collection systems to dispose of batteries.
13. EU/UK declaration of conformity
Hoffmann Supply Chain GmbH hereby declares that this wireless device complies with Directive 2014/53/EU and the UK Ra-
dio Equipment Regulations 2017. The complete text of the declaration of conformity is available at hoffmann-group.com/
service/downloads/doc. The obligations of Hoffmann Supply Chain GmbH are fulfilled in the United Kingdom by Hoffmann
UK Quality Tools Ltd, Holborn Hill, Birmingham, B7 5JR, United Kingdom.
14. Technical data
Designation
Value
Working range of contact point
6 mm
Accuracy during length measurement
+/- 0.01 mm
Repetition accuracy
+/- 0.005 mm
Reach of signal transmission (available field)
10 m
Transmission power
8 dBm
Frequency range
2.402 to 2.48 GHz