GAT ECO.Lock 7xxx F/ISO
Configuration
46
HB_GAT-ECOLock-7xxxFISO--EN_12
www.gantner.com
6.5.4 Duration of Use
Lockers operating in free locker mode can be configured to limit the user to a defined period of use. See section
“5.2.1. Free Locker Mode (with or without Duration of Use Function)” for detailed information. The duration of use
function is found here:
Configuration > Operating mode > Free Locker
► Select either “Duration” or “Point of time” from the “Use time limit” menu for the type of time limit.
► Define the time limit in minutes in the “Time limit (min)” field.
6.5.5 Pre-Lock Personal Locker
The pre-lock function for personal lockers allows the locker to lock automatically when the locker door is pushed
shut, without needing to use a data carrier. The locker can be unlocked again using the data carrier(s) authorized to
use the personal locker. The function is found here:
Configuration > Operating mode > Personal Locker > PreLock Personal Locker
► Select / deselect the “PreLock Personal Locker” option to turn the function on / off.
6.5.6 RF Standards
The GAT ECO.Lock 7xxx F/ISO can operate with data carriers that use ISO 15693 and ISO 14443A (MIFARE)
technology.
The default setting for the GAT ECO.Lock 7xxx F/ISO is to operate with ISO 14443A (MIFARE) data carriers.
The setting for the GAT ECO.Lock 7xxx F/ISO to operate with ISO 14443A (MIFARE) data carriers cannot be
changed. The setting for the GAT ECO.Lock 7xxx F/ISO to operate with ISO 15693 data carriers can be adjusted
and is found here:
Configuration > Reader > RF Standards > ISO 15693
► Select / deselect the “ISO 15693” option to turn the setting on / off.
6.5.7 Master Cards
Up to 10 master cards can be assigned to the GAT ECO.Lock 7xxx F/ISO to allow the locker to be opened in
special circumstances, e.g., when a user has lost their data carrier. For this functionality, the master cards must be
first assigned to the GAT ECO.Lock 7xxx F/ISO, which is done here:
Configuration > Application > Master cards > Master Card 1 - 10
► Enter the number of each master card (data carrier) into the respective fields.
NOTE!