When one of the data carriers assigned to a guest is used at the locker for the first time, the expiry date and the
index value of the data carrier are transferred to the GAT ECO.Lock 7xxx F/ISO.
Locking and unlocking lockers
► Close the locker door and hold it shut.
► Press the button of the GAT ECO.Lock 7xxx F/ISO in using the data carrier for approximately 1 second.
o
The information on the data carrier is read. The locker number on the data carrier must correspond
with the locker number in the lock
► The following situations are possible. The data carrier…
1)
…is the first data carrier used at the locker:
o
The index value and the "valid to" date of the data carrier are saved in the lock. The data carrier can
lock and unlock the locker until the end of the validity period.
2)
…has the same index value and "valid to" date as stored in the lock:
o
The data carrier is now authorized to lock and unlock the locker like the previously authorized data
carriers.
3)
…has a higher index value than in the lock:
o
The new index value and the "valid to" date of the data carrier are saved in the lock. The previously
authorized data carriers are no longer authorized to use the locker.
4)
…has the same index value and a newer "valid to" date than in the lock:
o
The index value and the new "valid to" date of the data carrier are saved in the lock. The previously
authorized data carriers are no longer authorized to use the locker.
NOTE!
Situation 2) is possible when the locker is locked or unlocked. Situations 3) and 4) are possible with a
locked or unlocked locker except when the "PersonalLockerSecureFlag" option is set (see "6.5.8. Configuration
Settings Table"). With this option set, the procedure is only possible with an open (unlocked) locker.
► Release the locker door.
► a) Valid data carriers: The information on the data carrier is saved in the lock. The locker state will switch, i.e., the
locker will open when it was locked or will lock when it was open.
b) Invalid data carriers: The LED flashes red briefly and the GAT ECO.Lock 7xxx F/ISO switches off without
carrying out an action.
There is also no unlimited usage period for the locker, i.e., the expiry date must be a valid date (not "0"). If the "valid to"
date is exceeded, the locker can no longer be opened using the data carrier except when the
"LastOpenAtExpiredDate" option is set (see "6.5.8. Configuration Settings Table"). With this option set, the locker
can be opened one more time using the data carrier.