GAT ECO.Lock 7xxx F/ISO 
Operation

 

 
 

32             

HB_GAT-ECOLock-7xxxFISO--EN_12  

 

 

www.gantner.com

 

5.2.1  Free Locker Mode (with or without Duration of Use Function)  

 

In "free locker" operating mode, the user has the option of selecting a free locker and locking it using their data 
carrier. After the locker has been locked, the user cannot occupy any additional lockers within the same locker 
group. Only once the original locker has been unlocked can the user lock another locker in the locker group. 
 
Locker groups are used to organize the locks within a system into certain functional blocks, e.g., changing room 
lockers, safe-deposit boxes, etc. Different sector numbers are used on the data carriers to distinguish between the 
locker groups, which allows two or more lockers from different groups to be used with the same data carrier, 
depending on the data carrier storage space. 
 
For data carriers that are configured with an expiry date, the date is checked by the GAT ECO.Lock 7xxx F/ISO. If 
the date has passed, the locker cannot be used. 
  

NOTE!

 The GAT ECO.Lock 7xxx F/ISO does not automatically adjust to summer/winter time changes. This must 

be taken into account when defining the validity or expiry date. 
 
Duration of Use function 
Free locker mode also offers the possibility to define a duration of use for each locker. If a locker with this function is 
locked with a data carrier, the current time is written onto the data carrier and the time subsequently checked when 
the user attempts to open the locker again. 
 
The locker can be locked/unlocked as often as required during the duration of use period. If the duration of use 
period is exceeded, the data carrier can no longer unlock the locker. In this case, the user must recode their data 
carrier at a central station, e.g., a GAT Info 6800 F with additional coding license (Part No. 193732). 
 
The data carrier must be coded accordingly for the duration of use function (the corresponding config bits on the 
data carrier must be set). In addition, the GAT ECO.Lock 7xxx F/ISO must be configured in GAT Config Manager 
for the function (see section “6.5.4. Duration of Use”). There are two configuration modes for the function: 
 
Absolute duration of use (“Duration” function) 
In this mode, a usage period 

(depending on the “Time limit” parameter in minutes or hours, see "6.5.8 Configuration 

Settings Table") is configured. After locking a locker, the user must unlock the locker again within the defined 
period. The period begins from when the locker was first locked.   

Example:  
The time is set to 360 minutes. If the locker is locked at 17:00, it can be unlocked until 23:00. If the locker is locked 
at 21:00, it can be unlocked until 03:00 of the next day. The duration of use time is reset after the locker remains 
open for 60 minutes.  
 
Use up to a specific time after midnight (“Point of time” function) 
In this mode, a time is configured up to which the locker can be used every day. After locking a locker, the locker 
must be unlocked before the defined time. The usage period starts from the configured time after midnight. 

Example:  
The time is set to 120 minutes. As the calculation begins at midnight, the locker can be used until 02:00 the 
following day regardless of when the locker was locked. If the locker is locked, e.g., at 01:00, it can be unlocked 
until 02:00 of the following day. If the locker remains locked past this time, the data carrier can no longer unlock the 
locker. In this case, the user must recode the data carrier at a central station.  
 

Summary of Contents for Mifare Gat ECO.Lock 7 F/ISO Series

Page 1: ...AT ECOLock 7xxxFISO EN_12 1 GAT ECO Lock 7xxx F ISO Battery Powered Electronic Lock MIFARE and ISO 15693 Installation Configuration Operation Document Version 1 2 Installation Configuration Operation...

Page 2: ...pend exclusively on the conditions of the guarantee Any further reaching claims are excluded and in particular the manufacturer accepts no liability for the completeness or accuracy of the contents of...

Page 3: ...e installation commissioning and servicing of our products must be performed by suitably trained personnel In particular electrical connections must only be made by correspondingly qualified specialis...

Page 4: ...n a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to ra...

Page 5: ...Hole 18 3 7 2 Measurements for the Button Drill Hole 19 3 7 3 Installation Instructions for Non Metallic Doors 20 3 8 Installation in Lockers with Metallic Doors 21 3 8 1 Measurements for the Button D...

Page 6: ...figuration Settings 43 6 4 Upload Configuration Settings to the GAT ECO Lock 7xxx F ISO 44 6 5 Configuration Settings of the GAT ECO Lock 7xxx F ISO 45 6 5 1 Operating Mode 45 6 5 2 Locker Number 45 6...

Page 7: ...required to maintain the locker system and the LED signaling are also explained in this section In chapter 6 CONFIGURATION you will find information on how to configure the GAT ECO Lock 7xxx F ISO us...

Page 8: ...function critical information is displayed in this manual using the following formatting with sample text These instructions must be read and followed NOTE This signal word is used to indicate importa...

Page 9: ...oftware The lock can operate in one of five operating modes thereby providing flexibility for different locking requirements within a facility Using a locker To use a locker the user closes the door o...

Page 10: ...echnology the device supports B LEGIC F MIFARE ISO ISO 15693 The GAT ECO Lock 7xxx F ISO can operate with data carriers using MIFARE and ISO 15693 technologies It is necessary for all devices and data...

Page 11: ...lockers For outdoor lockers ext temp range IP 64 For metallic lockers Figure 2 1 Components of the GAT ECO Lock 7xxx F ISO system 1 GAT ECO Lock 7100 F ISO 2 GAT ECO Lock 7100 NW F ISO 3 GAT ECO Lock...

Page 12: ...200 Adapter Part No 614322 Adapter for GAT ECO Lock 7100 to cover a 38 mm drilling in metal doors No screws required 6 GAT ECO Basic Set F ISO Part No 812528 Accessory set for configuring and maintain...

Page 13: ...SO EN_12 13 2 5 GAT ECO Lock 7xxx F ISO Dimensions and Components Non metallic door Metallic door 1 Battery cover 4 LED ring 2 Locking bolt 5 Lock electronics 3 Button 6 Booster Figure 2 2 GAT ECO Loc...

Page 14: ...and unlocks as required ideally using a data carrier of the same type to be used with the locker system to ensure that the data carrier functions as required 3 2 Replacement after a Burglary Attempt I...

Page 15: ...O Lock 7xxx F ISO is suitable for locker doors with a maximum door leaf thickness of 28 mm 1 1 When installing the GAT ECO Lock 7xxx F ISO into lockers with narrow doors ensure that the lock housing d...

Page 16: ...ght hinged door Left hinged door Figure 3 2 Locker door hinge definition left right The position of the locking bolt and button of the GAT ECO Lock 7xxx F ISO is different for right and left hinged do...

Page 17: ...e GAT ECO Lock 7xxx F ISO to suit a right or left hinged locker door can be carried out easily by completing the following steps Lift the lock electronics out of the lock housing Rotate the lock elect...

Page 18: ...lling all locks in a new locker system a test installation of one lock into a completed locker and a function check must be performed See section 3 1 Test Installation 3 7 1 Measurements for the Butto...

Page 19: ...imum door leaf thickness of 28 mm 1 1 For locker doors that do not adhere to these measurements or for doors with an unfixed pivot point depending on the type of hinge used the distance between the lo...

Page 20: ...before the GAT ECO Lock 7xxx F ISO See 3 10 Door Handle Installation Optional for more information Mount the GAT ECO Lock 7xxx F ISO onto the inside locker door using 4 screws Hardware recommendation...

Page 21: ...talling all locks in a new locker system a test installation of one lock into a completed locker and a function check must be performed See section 3 1 Test Installation 3 8 1 Measurements for the But...

Page 22: ...door it is recommended to install the lock a corresponding distance away from the locker door e g using a mounting bracket as shown below in Figure 3 9 This installation method allows the lock to be...

Page 23: ...surements in Figure 3 8 and Figure 3 5 for right hinged doors or Figure 3 6 for left hinged doors If you are also using the optional GAT Lock Door Handle this must be installed before the GAT ECO Lock...

Page 24: ...inged door GANTNER provides the following labels Frontfolie GAT Lock 6010 GANTNER o Nr Part No 666834 Self adhesive locker door label in GANTNER design without numbering Frontfolie GAT Lock 6010 GANTN...

Page 25: ...ll the GAT Lock Door Handle On the door outer side drill 4 blind holes 2 diameter 8 mm and depth 9 mm around the lock button hole according to the measurements in Figure 3 12 On the door inner side dr...

Page 26: ...ounted onto the door inner side The installation instructions for metallic or non metallic doors are provided in the previous chapters 1 GAT Lock Door Handle 2 GAT ECO Lock 7xxx F ISO 3 GAT ECO Lock 7...

Page 27: ...The GAT ECO Lock 7xxxx F ISO indicates a weak battery state with five red flashes of the LED ring and five acoustic signals during a locking attempt NOTE For optimal battery lifespan use the approved...

Page 28: ...n the lock has already been used and the batteries are being replaced the lock must be activated using the battery cover key see 4 1 3 Replacing the Batteries Press the lock button in using the batter...

Page 29: ...the battery cover key 4 2 USB Connection A Micro B USB port is located on the opposite side of the GAT ECO Lock 7xxx F ISO to the locking bolt The USB port location on the side of the lock allows con...

Page 30: ...y are available on the Leisure Software USB stick which is included in the GAT ECO Basic Set F ISO The LED ring flashes alternating red green after connecting to the computer To activate configuration...

Page 31: ...ing a data carrier which is done by pressing the button completely in 5 2 Operating Modes The GAT ECO Lock 7xxx F ISO can function in one of the following operating modes Free locker with or without d...

Page 32: ...ded the data carrier can no longer unlock the locker In this case the user must recode their data carrier at a central station e g a GAT Info 6800 F with additional coding license Part No 193732 The d...

Page 33: ...e locker cannot be opened anymore In this case the data carrier must be reset at a central station Release the locker door 5 2 2 Free Locker Universal Mode Free locker universal operating mode differs...

Page 34: ...the same authorization access e g family cards The data carriers are authorized for use with the personal locker using the program data carrier included in the GAT ECO Basic Set F ISO see section 5 3...

Page 35: ...3 times and the GAT ECO Lock 7xxx F ISO switches off o All data carriers are now deleted from the GAT ECO Lock 7xxx F ISO and no longer have the authorization to use the locker any more 5 2 5 Persona...

Page 36: ...ed in the lock The previously authorized data carriers are no longer authorized to use the locker 4 has the same index value and a newer valid to date than in the lock o The index value and the new va...

Page 37: ...emergency opening of the corresponding locker can be carried out using a master data carrier Three master data carriers are included in the basic set and they are only valid for the respective system...

Page 38: ...the battery data carrier is used See section 4 1 3 Replacing the Batteries for more information After replacing the batteries of a GAT ECO Lock 7xxx F ISO in personal locker mode all settings stored i...

Page 39: ...the following lock states are signaled by the status LED LED Ring Meaning Blue flash Lock ready to read a data carrier Red flash No authorization Error Green flash Data carrier accepted Operation succ...

Page 40: ...GAT ECO Lock 7xxx F ISO Operation 40 HB_GAT ECOLock 7xxxFISO EN_12 www gantner com...

Page 41: ...ng Modes Free locker Sector number of the data on the data carrier and the time setting for the duration of use function Date and time set automatically Unique numbers of the master data carriers The...

Page 42: ...ure 6 1 to find an existing project Alternatively click on the Create Project icon 2 in Figure 6 1 to start a new project Figure 6 1 GAT Config Manager Project setup Once a project is established loca...

Page 43: ...nnected GAT ECO Lock 7xxx F ISO has been added to the Devices directory you can now view and adjust the lock configuration settings Complete the following steps to view the configuration settings Sele...

Page 44: ...7xxx F ISO When you are finished configuring the GAT ECO Lock 7xxx F ISO settings in GAT Config Manager it is important to finalize the configuration by uploading the file to the GAT ECO Lock 7xxx F I...

Page 45: ...programming card Personal locker expiry date or Free locker unique number 6 5 2 Locker Number The number of the locker where the GAT ECO Lock 7xxx F ISO is installed can be defined The locker number...

Page 46: ...select the PreLock Personal Locker option to turn the function on off 6 5 6 RF Standards The GAT ECO Lock 7xxx F ISO can operate with data carriers that use ISO 15693 and ISO 14443A MIFARE technology...

Page 47: ...er that locked it see 5 2 5 Personal Locker Expiry Date Mode Boolean False Free Locker Use TimeLimit Select the type of time limit for the locker see 5 2 1 Free Locker Mode with or without Duration of...

Page 48: ...egment where general data is stored Integer 13 Certificate Block Num The segment where certificate data is stored Integer 15 Locker Block Num The segment where locker data is stored Integer 19 Gantner...

Page 49: ...ing Field Reader type MIFARE supported types MIFARE Classic 1k and 4k MIFARE Ultralight DESFire EV1 and EV2 ISO 15693 Note It is recommended to have customer specific data carriers approved by GANTNER...

Page 50: ...pability DIN 4547 2 class C 7 7 Environmental Conditions Permitted ambient temperature Indoor model 0 C to 55 C 32 F to 131 F Outdoor model 25 C to 55 C 13 F to 131 F Protection type Indoor model IP 5...

Page 51: ......

Page 52: ...ntner com info syx nl info aus gantner com London UK Bochum Deutschland Los Angeles USA T 44 178 249 9195 T 49 234 58896 0 T 1 844 703 1139 info syxautomations co uk info de gantner com info us gantne...

Reviews: