15
4.6.4
External relay connections
Commander 1114 is equipped with a single, normally open relay
contact on CON15:
This contact is programmable via the unit's web pages to give a
variety of different functions, such as activation on ringing, or off-
hook, etc. Refer to the configuration guide for full details (available
from
www.gai-tronics.org/support/voip-support/
CONTACT RATING:
Maximum voltage = 253Vrms (nominal 230V)
Maximum current = 5A
Note: no fusing or transient protection is provided; this must be
installed externally.
The relay fitted to the Commander 1114 has a continuous current
rating of 5A. It has been brought to our attention that some beacons,
whilst having a current rating well below this figure, actually generate