Commander 1114 VoIP
14
B), not data pair. Ensure that your PoE switch or injector
can provided PoE by this method.
Or
•
Isolated DC supply on CON 6:
24 – 48Vdc nominal (the limits are 22-53Vdc)
250mA
4.6.3
Earth connection
The Commander 1114 has an earth point which needs to be
connected to the equipotential bonding system for the whole area in
which the equipment is being used, using one of the following:
1. At least two separate conductors each with a copper cross
sectional area of 1.5mm
2
(minimum).
Or
2. At least one conductor with a copper cross sectional area of
4mm
2
(minimum).
The earth point is connected to 2 earth studs on the case – one
available externally and one internally.