current spikes far in excess of this during making and breaking of the
relay contacts. These current spikes can cause the relay contacts to
fail.
GAI-Tronics have been working closely with Beacon manufacturer,
to resolve this issue and our recommendations are:
•
Restrict the use of beacons to non AC variants only or those
with a maximum flash intensity of 5 joules.
•
Where beacons with greater than 5 joule flash intensity are
required, the beacons should be purchased direct from GAI-
Tronics, who will carry out a free of charge modification to the
beacon to ensure compatibility with the Commander 1114.
4.6.5
Alternative cabling schemes
Upon installation care should be taken to ensure that incoming
cables are cleanly routed with a view to maintaining segregation
from the telephone's internal wiring (i.e. handset, hookswitch, ringer
and headset if fitted).