1. OPERATIONAL OVERVIEW
1-39
1.35
Dynamic Range
In radar systems, system dynamic range is crucial for differentiating between highly reflective tar-
gets and those which do not have optimum reflective properties. You may change the dynamic
range to better differentiate those targets as below.
1. Press the
MENU
key to open the menu.
2. Choose the Echo menu and then press the
ENTER
key.
3. Choose Display-Dynamic and then press the
ENTER
key.
4. Choose Narrow (-6dB), Normal(-12dB) or Wide(-18dB) as appropriate and then press the
ENTER
key.
Dynamic range settings
5. Press the
MENU
to close the menu.
1.36
Characteristics Curve
The characteristics curve of this radar may be changed to meet detection requirement.
1. Press the
MENU
key to open the menu.
2. Choose the Echo menu and then press the
ENTER
key.
3. Choose Display-Curve and then press the
ENTER
key.
4. Choose 1 (Linear), 2(Exponential) or 3(Logarithm) as appropriate and then press the
ENTER
key.
5. Press the
MENU
to close the menu.
Narrow
Normal
Wide
6 db
12 db
18 db
Wide
Normal
Narrow
Narrow
Normal
Wide