Programming Guide
8-14
8.2.7.
Parameter Table
Parameter Table for Fusion Program
Parameter name
Min
Max
Description
For Splice
1st Arc Start Power
0
200
Starting arc power in 1
st
arc discharge.
1st Arc End Power
0
200
Ending arc power in 1
st
arc discharge.
2nd Arc Start Power
0
200
Starting arc power in 2
nd
arc discharge
2nd Arc End Power
0
200
Ending arc power in 2
nd
arc discharge.
Arc Power Compensation
-127
128
Corrects the arc power based on the axis offset of the
fibers
Cleaning Arc Power Offset
-127
128
Additional Arc Power for cleaning purposes
Cleaning Duration [ms]
0
32767 Arc duration for cleaning [msec]
Pre-fuse Duration [ms]
0
32767 Time between arc starting and fibers first butting [msec]
1st Arc Duration [ms]
0
32767 1
st
arc time duration [msec].
2nd Arc Duration [ms]
0
32767 2
nd
arc time duration [msec].
Z Pull Start Time [ms]
0
32767 Time to start to pull back the fiber [msec].
Z Push Distance [µm]
0
32767
Overlapping distance from fibers first butting position
[µm].
Z Pull Distance [µm]
0
32767
Pulling back distance from the final overlapping position
[µm].