![Furukawa electric S153 Ver.2 User Manual Download Page 73](http://html.mh-extra.com/html/furukawa-electric/s153-ver-2/s153-ver-2_user-manual_2349542073.webp)
Operating Instructions
7-11
Wrong Fusion Program
selected
Select the correct Fusion Program,
and repeat fusion splicing.
Excessive fiber feed
Adjust the fiber feed amount.
Degradation
of
electrodes
Replace electrodes.
Thickening
Excessive arc current
Perform an arc check, and adjust arc
power.
Wrong Fusion Program
selected
Select the correct Fusion Program,
and repeat fusion splicing.
Degradation of
electrodes
Replace the electrodes.
Streak
Weak arc
Perform an arc check and adjust arc
power, or apply an additional arc.