Error Messages
Error Description
Cause of the error
Action
Fiber is not loaded or
not in the proper
position.
Load the fiber at the
proper position.
Inappropriate fiber
program is selected.
Check and correct the
program.
Bad cleaving quality.
Prepare the fiber
again and retry.
Defect in the motor
driving system.
Contact service
center.
OVER-RUN
(with name of the
failed motor)
The motor detected
the overrun limit when
running forward.
V-groove is dirty
Clean the V-groove.
Incorrect parameter is
set for heating.
Check and correct the
parameters.
HEAT TIME OUT
The temperature
does not reach the
set value within the
time limit from heating
start up.
Defect in the heating
system.
Contact service
center.