Operating Instructions
7-8
Menu: Display the Menu Screen.
Zoom: Zoom in on the fiber image.
Capture: Capture the fiber image and store it with the splice data.
Field Change: Switch the fiber view between X and Y.
♦
If an abnormality was detected in the process, the estimated loss is displayed with “>”
instead of “=”, to indicate the error occurrence in the cycle. (Example: LOSS > 0.04dB)
♦
To discharge an additional arc, press
; splice inspection and loss estimation are
re-performed.
♦
If the fibers fail the inspections
for cleave criteria, the fusion
cycle
is
paused
and
an
appropriate error message is
displayed as below. Open the
windshield, remove the fibers
after READY is displayed and
retry the splice by repeating the
entire procedure, starting from the fiber preparation process. To ignore the error and
continue the cycle, press
again.