System fan and air duct
8.3.3
Installing the new system fan
Ê
Insert the system fan into the air duct.
Figure 73: Installing the system fan in the air duct
Ê
Push the system fan on the snap rivets (1).
I
Notice the position of the fan cable. Ensure that the fan cable is not
pressed.
Ê
Insert and tightly push the four safety pins into the snap rivets (2).
Ê
Insert the fan cable in the guidings (see figure
70
).
8.3.4
Concluding steps
Ê
"Installing the fan module" on page 152
Ê
"Reassembling" on page 58
Ê
"Connecting the server to the mains" on page 67
Ê
"Switching on the server" on page 68
Ê
"Performing a fan test after replacing a defective fan" on page 96