![Fujitsu PRIMERGY RX800 S2 Operating Manual Download Page 20](http://html.mh-extra.com/html/fujitsu/primergy-rx800-s2/primergy-rx800-s2_operating-manual_121191020.webp)
14
U41621-J-Z156-1-76
Technical Data
Introduction
1.4
Technical Data
Electrical Data
Rated voltage range
100 V to 127 V AC
200 V to 240 V AC
(auto sense)
Frequency
50 Hz / 60 Hz
Max. mains current
8,5 A / 8,5 A
Apparent power (max.)
1600 VA
Effective power (max.)
1300 W
Heat emission (max.)
6098 kJ/h (5780 BTU)
Building fuse
16 A
Protection class
I
Table 3: Electrical data
Dimensions and Weight
Height (mm)
128.35 (3 U)
Width (mm)
440
Depth (mm)
715 mm
Rack mount depth (mm)
715 mm, incl. SMP cable 815 mm;
Rack height units
3/6/12 U (4/8/16-way)
Rack cable depth
100 mm (900 mm rack sufficient, 1000
mm rack recommended)
Rack integration kit
inclusive telescopic rails as part of the
standard delivery
Weight (kg)
~ 38.5 kg (per 3 U system unit)
Table 4: Dimensions and weights