![Fujitsu PRIMERGY RX800 S2 Operating Manual Download Page 101](http://html.mh-extra.com/html/fujitsu/primergy-rx800-s2/primergy-rx800-s2_operating-manual_121191101.webp)
U41621-J-Z156-1-76
95
Troubleshooting and Tips
Error Controls and Indicators
LOG
Information is present in the
BMC log and system-error
log. One or both logs might
be full or almost full.
Ê
Save the log if necessary and
clear it (see “Event/Error Logs”
on page 61).
Ê
Check the log for possible errors
(see “Event/Error Logs” on
page 61).
MEM
Memory failure.
The error LED on the
memory card is also
lit.
Ê
Remove the memory card with
the lit error LED on the top of the
card; then, press the light path
button on the memory card to
identify the failed card or DIMM.
Ê
If one of the DIMM error LEDs
on the memory card is on, have
system serviced.
NMI
A hardware error has been
reported to the operating
system (Non-maskable
interrupt occurred).
The PCI or MEM
LED might also be lit.
Ê
See the BMC log and the
system-error log (see
“Event/Error Logs” on page 61).
Ê
If the PCI LED is lit, follow the
instructions for that LED.
Ê
If the MEM LED is lit, follow the
instructions for that LED.
Ê
Restart the server.
Ê
If problem persists, have system
serviced.
PCI
A PCI-X adapter has failed.
The error LED next
to the failing adapter
on the PCI-X adapter
is also lit.
Ê
See the BMC log or the system-
error log (see “Event/Error
Logs” on page 61).
Ê
If problem cannot be traced,
have the system serviced.
SP
There is a fault in the
Remote Service Adapter II.
Ê
Call for service.
Lit LED on
LED Card
Cause
Action
Table 9: Indicators on the LED Card
i
i
i