![Fujitsu PRIMERGY RX800 S2 Operating Manual Download Page 103](http://html.mh-extra.com/html/fujitsu/primergy-rx800-s2/primergy-rx800-s2_operating-manual_121191103.webp)
U41621-J-Z156-1-76
97
Troubleshooting and Tips
Error Controls and Indicators
Remind Button
You can use the Remind Button on the LED card (see “LED Card Layout, seen
from top” on page 92) to put the system-error LED on the Operator Information
Panel into Remind mode. When you press the Remind Button, you
acknowledge the error, but indicate that you will not take immediate action. The
system-error LED flashes while it is in Remind mode and stays in Remind mode
until one of the following conditions occurs:
●
All known errors are corrected.
●
The server is restarted.
●
A new error occurs, causing the system-error LED to be lit again.
FAN
A fan has failed or has been
removed.
A failing fan can also
cause the TEMP
LED to be lit.
Ê
Reinstall the removed fan.
Ê
If an individual fan LED is lit,
replace the fan (see page 112).
Ê
If problem persists, call for
service.
PCI BRD
The PCI-X adapter has
failed.
Ê
Call for service.
CPU BRD
The microprocessor tray
has failed.
Ê
Call for service.
I/O BRD
The I/O board has failed.
Ê
Call for service.
Lit LED on
LED Card
Cause
Action
Table 9: Indicators on the LED Card
i