![Fujitsu PRIMERGY RX800 S2 Operating Manual Download Page 107](http://html.mh-extra.com/html/fujitsu/primergy-rx800-s2/primergy-rx800-s2_operating-manual_121191107.webp)
U41621-J-Z156-1-76
101
Troubleshooting and Tips
Miscellaneous Problems
5.2.9
Added Drive Defective
RAID controller is not configured for this hard disk drive
The drive was installed with the system switched OFF.
Ê
Reconfigure the RAID controller for the drive with the corresponding utility.
Information is contained in the documentation on the RAID controller.
or
Ê
Re-insert the HDD module with the system switched ON into a free module
bay.
If the hard disk drive continues to be shown as defective, then replace it (see
section “Hot-plug Hard Disk Drives” on page 104).
5.2.10 Error Messages on the Monitor
The meaning of the error messages is explained in the documentation for the
relevant components and programs on the PRIMERGY
ServerBooks
CD.