28
Operating manual
RX
300 S6
Technical data
Mechanical values
Weight
Approx. 25 kg (depending on configuration).
Ventilation clearance
At least 200 mm on the front and rear.
Environmental conditions
Condensation must be avoided during operation.
Noise level
Width
482.4 mm
Depth
770 mm
Height
85.9 mm or 2HU
Installation depth in rack 735 mm
Cable depth in rack
100 mm (1000 mm rack recommended)
Environment class 3K2
Environment class 2K2
Environment class 3.1
EN 60721 / IEC 721 part 3-3
EN 60721 / IEC 721 part 3-2
ETX 300-019-2-3; T3.1
Temperature:
Operating (3K2)
10°C ....35°C
Transport (2K2)
- 25°C .... 60°C
Humidity
10% ..... 85%
Mechanical environmental
conditions
Operating: EN 60721-3-3; class 3M2
Transport: EN 60721-3-2; class 2M2
Sound power level L
WAd
(ISO 9296)
< 6.2 B (standby)
< 6.2 B (operation)
Sound pressure level at adjacent workstation
L
pAm
(ISO 9296)
< 45 dB(A) (standby)
< 45 dB(A) (operation)
Summary of Contents for PRIMERGY RX300 S6
Page 1: ...Operating manual English PRIMERGY RX300 S6 Operating manual Edition March 2011 ...
Page 6: ...Operating manual RX 300 S6 ...
Page 10: ...Operating manual RX 300 S6 9 Appendix server specification 121 Index 125 ...
Page 86: ...86 Operating manual RX 300 S6 Cleaning the server ...
Page 88: ...88 Operating manual RX 300 S6 BIOS Setup security functions ...
Page 120: ...120 Operating manual RX 300 S6 Opening closing the housing ...