32
Operating manual
RX
300 S6
Safety instructions
Before starting up
V
CAUTION!
●
During installation and before operating the device, observe the
instructions on environmental conditions for your device.
●
If the device is brought in from a cold environment, condensation may
form both inside and on the outside of the device.
Wait until the device has acclimatized to room temperature and is
absolutely dry before starting it up. Material damage may be caused
to the device if this requirement is not observed.
●
Transport the device only in the original packaging or in packaging
that protects it from knocks and jolts.
Installation and operation
V
CAUTION!
●
This unit should not be operated in ambient temperatures above
35 °C.
●
If the unit is integrated into an installation that draws power from an
industrial power supply network with an IEC309 connector, the power
supply's fuse protection must comply with the requirements for non-
industrial power supply networks for type A connectors.
●
The unit automatically adjusts itself to a mains voltage in a range of
100 V - 240 V. Ensure that the local mains voltage lies within these
limits.
●
This device must only be connected to properly grounded power
outlets or insulated sockets of the rack's internal power supply with
tested and approved power cords.
●
Ensure that the device is connected to a properly grounded power
outlet close to the device.
Summary of Contents for PRIMERGY RX300 S6
Page 1: ...Operating manual English PRIMERGY RX300 S6 Operating manual Edition March 2011 ...
Page 6: ...Operating manual RX 300 S6 ...
Page 10: ...Operating manual RX 300 S6 9 Appendix server specification 121 Index 125 ...
Page 86: ...86 Operating manual RX 300 S6 Cleaning the server ...
Page 88: ...88 Operating manual RX 300 S6 BIOS Setup security functions ...
Page 120: ...120 Operating manual RX 300 S6 Opening closing the housing ...
Page 130: ...130 Operating manual RX 300 S6 ...