Weight
Dimensions (Base unit specific)
Environmental
Electrical values
Weight
up to 25 kg
Weight notes
Weight may vary depending on actual configuration
Rack mounting kit
Rack mounting kit as option
Rack (W x D x H)
482.4 x 770 (with handles) x 85.9 mm
Mounting Depth Rack
735 mm
Noise emission
Measured according to ISO 7779 and declared
according to ISO9296
Sound pressure
(LpAm)
45 dB(A) (idle) / 45 dB(A) (operating)
Sound power (LWAd;
1B = 10dB)
6.2 B (idle) / 6.2 B (operating)
Operating ambient
temperature
10 - 35 °C
Operating relative
humidity
10 - 85 % (non condensing)
AC power supply
DC power supply
Power supply
configuration
Base unit specific: 1x hot-plug power supply or
2x hot plug power supply for redundancy
Max. output of hot-plug
power supply
800 W
Rated voltage range
100 V - 240 V
40.5 V - 57 V
Rated frequency range 50 - 60 Hz
DC
Rated current
max. 8.0 A – 3.5 A /
100 V - 240 V
23.8 A - 16.4 A /
40.5 V - 57 V