93
Added drive reported as defective
7.9
Added drive reported as defective
RAID controller is not configured for this drive
The drive was probably installed when the system was switched off.
Ê
Reconfigure the RAID controller for the drive using the corresponding utility.
Information is provided in the documentation for the RAID controller.
or
Ê
Remove and reinstall the drive while the system is switched ON.
If the hard disk drive continues to be shown as defective, then replace it (see
"Hot-plug disk drives" on page 100
).
7.10
Error message on screen
The meaning of the error message is explained in the documentation for the
relevant components and programs on the ServerView Suite DVD 2.
7.11
Expansion cards or onboard devices not
recognized
When an expansion card is added, other expansion cards or onboard devices
might not be recognized.
Ê
Reinstall the drivers for the expansion cards or onboard devices that are not
recognized.
7.12
Temperature warning
A temperature warning is output to the hardware event log and OS event log, or
ServerView issues a notification of a temperature warning such as by a popup
message
Summary of Contents for PRIMERGY RX300 S6
Page 1: ...Operating manual English PRIMERGY RX300 S6 Operating manual Edition March 2011 ...
Page 6: ...Operating manual RX 300 S6 ...
Page 10: ...Operating manual RX 300 S6 9 Appendix server specification 121 Index 125 ...
Page 86: ...86 Operating manual RX 300 S6 Cleaning the server ...
Page 88: ...88 Operating manual RX 300 S6 BIOS Setup security functions ...
Page 120: ...120 Operating manual RX 300 S6 Opening closing the housing ...
Page 130: ...130 Operating manual RX 300 S6 ...