RX2540 M4
Upgrade and Maintenance Manual
307
Expansion cards and backup units
9.10.6 Replacing a riser card
9.10.6.1 Preliminary steps
Ê
"Suspending BitLocker functionality" on page 91
Ê
"Locating the defective server" on page 53
Ê
"Shutting down the server" on page 55
Ê
"Disconnecting the power cord" on page 56
Ê
Remove all external cables from the expansion card to be replaced.
Ê
"Getting access to the component" on page 58
Ê
If applicable, disconnect internal cables to the expansion card.
Ê
Locate the defective riser card using the onboard Local Diagnostic LEDs,
see section
"Onboard indicators and controls" on page 551
.
9.10.6.2 Removing the defective riser card
Ê
If applicable, remove the riser module 1, see section
.
Ê
If applicable, remove the riser module 2, see section
.
Ê
Remove the GPGPU card, see section
"Removing a GPGPU card (FL)" on
Ê
Remove the riser card, see section
"Removing the riser card" on page 72
9.10.6.3 Installing the new riser card
Ê
Install the new riser card, see section
"Installing the riser card" on page 73
Ê
Install the new GPGPU card, see section
"Installing a GPGPU card in a riser
.
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Software: 5 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver / hexagon screw driver 5 mm
Summary of Contents for PRIMERGY RX2540 M4
Page 40: ...40 Upgrade and Maintenance Manual RX2540 M4 Before you start ...
Page 90: ...90 Upgrade and Maintenance Manual RX2540 M4 Basic hardware procedures ...
Page 136: ...136 Upgrade and Maintenance Manual RX2540 M4 Power supply unit PSU ...
Page 228: ...228 Upgrade and Maintenance Manual RX2540 M4 Hard disk drives HDD and solid state drives SSD ...
Page 344: ...344 Upgrade and Maintenance Manual RX2540 M4 Main memory ...
Page 362: ...362 Upgrade and Maintenance Manual RX2540 M4 Processor CPU ...
Page 390: ...390 Upgrade and Maintenance Manual RX2540 M4 Liquid cooling LC ...
Page 498: ...498 Upgrade and Maintenance Manual RX2540 M4 Additional interfaces ...
Page 572: ...572 Upgrade and Maintenance Manual RX2540 M4 Appendix A ...
Page 574: ...574 Upgrade and Maintenance Manual RX2540 M4 Appendix B ...
Page 582: ...8 RX2540 M4 Basic Serial RS 232 Cable plan System Board D3384 RS 232 onboard RS 232 rear C6 ...
Page 634: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...