RX2540 M4
Upgrade and Maintenance Manual
53
4
Basic hardware procedures
4.1
Using diagnostics information
Use the Fujitsu ServerView Suite management software to plan the upgrade or
replacement of hardware components:
Ê
In the ServerView Operations Manager
Single System View
select
Maintenance
from the
Information/Operation
menu.
It is recommended to prepare local maintenance tasks using remote diagnostics
procedures, see the "ServerView Suite Local Service Concept (LSC)" manual.
I
In Japan remote diagnostics procedures are not used.
Please contact your local Fujitsu customer service partner for details on the
service concept and on how to order expansion kits or spare parts.
Use the Fujitsu Illustrated Spares Catalog to identify the required spare part and
obtain technical data and order information. Illustrated Spares catalogs are
available online at
http://manuals.ts.fujitsu.com/illustrated_spares
I
In Japan the Fujitsu Illustrated Spares Catalog is not used.
4.1.1
Locating the defective server
For easy identification of the server, switch on the ID indicator, especially when
working in a datacenter environment or a server room.
Ê
Press the ID button on the front panel, use the iRMC web interface or the
ServerView Operations Manager user interface to switch on the system
identification LEDs.
I
For more information, see the "ServerView Suite Local Service
Concept (LSC)" manual and the iRMC user guides.
Ê
When using ServerView Operations Manager to toggle the ID indicator,
choose
Single System View
and press the
Locate
button.
Ê
Remember to switch off the ID indicator after the maintenance task has been
concluded successfully.
Summary of Contents for PRIMERGY RX2540 M4
Page 40: ...40 Upgrade and Maintenance Manual RX2540 M4 Before you start ...
Page 90: ...90 Upgrade and Maintenance Manual RX2540 M4 Basic hardware procedures ...
Page 136: ...136 Upgrade and Maintenance Manual RX2540 M4 Power supply unit PSU ...
Page 228: ...228 Upgrade and Maintenance Manual RX2540 M4 Hard disk drives HDD and solid state drives SSD ...
Page 344: ...344 Upgrade and Maintenance Manual RX2540 M4 Main memory ...
Page 362: ...362 Upgrade and Maintenance Manual RX2540 M4 Processor CPU ...
Page 390: ...390 Upgrade and Maintenance Manual RX2540 M4 Liquid cooling LC ...
Page 498: ...498 Upgrade and Maintenance Manual RX2540 M4 Additional interfaces ...
Page 572: ...572 Upgrade and Maintenance Manual RX2540 M4 Appendix A ...
Page 574: ...574 Upgrade and Maintenance Manual RX2540 M4 Appendix B ...
Page 582: ...8 RX2540 M4 Basic Serial RS 232 Cable plan System Board D3384 RS 232 onboard RS 232 rear C6 ...
Page 634: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...