RX2540 M4
Upgrade and Maintenance Manual
55
Basic hardware procedures
●
Checking the onboard indicators on the system board using the Indicate
CSS button, see section
"Using the CSS button on the system board" on
Using the CSS button on the system board
If the system has been powered off, the onboard indicators guides you to the
faulty component.
V
CAUTION
It is mandatory to disconnect all power cords from the system in order to
use the Indicate CSS functionality.
Ê
Shut down and power off the server.
Ê
Disconnect all power cords from the system.
Ê
Press the Indicate CSS button to highlight defective components, see
section
"Using the CSS button on the system board" on page 55
The indicator next to the defective component lights up.
4.2
Shutting down the server
V
CAUTION!
For more information, see chapter
"Important information" on page 41
I
This step is only required when upgrading or replacing non-hot plug
components.
Ê
Inform the system administrator that the server will be shut down and put
offline.
Ê
Terminate all applications.
Ê
Perform the required procedures described in the preliminary steps of each
upgrade or maintenance task.
Ê
Shut down the server.
I
If the system is running an ACPI-compliant operating system,
pressing the On/Off button will perform a graceful shutdown.
Ê
Switch on the ID indicator on the front panel and I/O panel of the server, see
section
Summary of Contents for PRIMERGY RX2540 M4
Page 40: ...40 Upgrade and Maintenance Manual RX2540 M4 Before you start ...
Page 90: ...90 Upgrade and Maintenance Manual RX2540 M4 Basic hardware procedures ...
Page 136: ...136 Upgrade and Maintenance Manual RX2540 M4 Power supply unit PSU ...
Page 228: ...228 Upgrade and Maintenance Manual RX2540 M4 Hard disk drives HDD and solid state drives SSD ...
Page 344: ...344 Upgrade and Maintenance Manual RX2540 M4 Main memory ...
Page 362: ...362 Upgrade and Maintenance Manual RX2540 M4 Processor CPU ...
Page 390: ...390 Upgrade and Maintenance Manual RX2540 M4 Liquid cooling LC ...
Page 498: ...498 Upgrade and Maintenance Manual RX2540 M4 Additional interfaces ...
Page 572: ...572 Upgrade and Maintenance Manual RX2540 M4 Appendix A ...
Page 574: ...574 Upgrade and Maintenance Manual RX2540 M4 Appendix B ...
Page 582: ...8 RX2540 M4 Basic Serial RS 232 Cable plan System Board D3384 RS 232 onboard RS 232 rear C6 ...
Page 634: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...