36
Operating Manual
RX220
Installing/Removing the Server into/from the Rack
Hardware Installation
4.3.5
Mounting into the Classic Rack
I
General information are provided in the Technical Manual for the Classic
(19-inch) Rack (see also
“Related Publications” on page 75
).
Ê
Mark the position of the attachment points for the telescopic rails and for the
server (front panel) on the support uprights.
Ê
Place the spring nuts to fasten the telescopic rails in the groove of the
support uprights at the marked attachment points as described in the
Technical Manual for the Classic (19-inch) Rack.
Ê
Adjust the position of the nuts in the groove until they lock into the correct
position.
Figure 6: Mounting the left telescopic rail into the Classic Rack
Ê
There is a guide nub (1) at both ends of the telescopic rail. Fit this nubs into
the oblong holes of the support uprights next to the spring nuts.
2
1
1 x M 5
1 x M 5
2