188
Upgrade and Maintenance Manual
RX200
S8
Expansion cards and backup units
9.5.5.2
Removing the FBU with the holder
Figure 128: Disconnecting the FBU cable from the RAID controller
Ê
Carefully disconnect the FBU cable from the RAID controller (see circle).
Figure 129: Removing the FBU with the holder
Ê
Lift up the green locking handle on the holder (see circle) while sliding the
holder in direction of the arrow as far as it will go.
I
After that, the shoulder screw caps on the chassis floor will rest in the
wide ends of the keyhole slots on the holder.
Ê
Lift the holder out of the chassis.