72
Upgrade and Maintenance Manual
RX200
S8
Basic software procedures
Ê
After completion of the flash process, remove the USB stick and restart the
server.
iRMC recovery procedure
I
For the Japanese market, follow the instructions provided separately.
Ê
Prepare a USB stick including the bootable iRMC firmware update image.
Ê
Ensure that the server has been shut down and disconnected from the
mains as described in section
"Shutting down the server" on page 46
.
Ê
Connect the USB stick to the USB port.
I
Ensure that only the USB device with the iRMC firmware is connected
to the USB port. Remove all other USB devices temporarily.
Ê
Connect the server to the mains while pushing the ID button on the front
panel. Ask a second person to help you if necessary.
Ê
Ensure that the Global Error indicator and the ID indicator are flashing to
indicate that the server is entering the iRMC recovery state.
Ê
Press the Power On / Off button. The system starts the POST process.
I
In iRMC recovery mode, the “FUJITSU” logo does not show up.
Ê
The system will detect the USB stick.
I
If the BIOS cannot identify the USB stick, the pop-up message
Failed to boot for Emergency flash. Please Reset now.
will show up in the center of the screen.
Ê
Choose the
Recovery_L
option from the update tool menu to start the iRMC
update process.
V
CAUTION!
Do not interrupt the iRMC upgrade process after it has started. If the
process is interrupted, the iRMC BIOS may be permanently
corrupted.
I
If the iRMC does not work after flashing, disconnect the system from
the mains and reconnect it again.
Ê
Shut down the server by pressing the power On / Off button.
Ê
Disconnect the server from the mains to exit the iRMC recovery state.
Summary of Contents for PRIMERGY RX200 S8
Page 30: ...30 Upgrade and Maintenance Manual RX200 S8 Before you start ...
Page 42: ...42 Upgrade and Maintenance Manual RX200 S8 Important information ...
Page 106: ...106 Upgrade and Maintenance Manual RX200 S8 Power supply ...
Page 130: ...130 Upgrade and Maintenance Manual RX200 S8 Hard disk drives solid state drives ...
Page 194: ...194 Upgrade and Maintenance Manual RX200 S8 Expansion cards and backup units ...
Page 210: ...210 Upgrade and Maintenance Manual RX200 S8 Main memory ...
Page 234: ...234 Upgrade and Maintenance Manual RX200 S8 Processors ...
Page 244: ...244 Upgrade and Maintenance Manual RX200 S8 Optical disk drive ...
Page 320: ...320 Upgrade and Maintenance Manual RX200 S8 Cables ...