System board and components
Ê
Save your changes and exit the BIOS.
I
For detailed information on how to access the BIOS and modify
settings, refer to the corresponding BIOS Setup Utility reference
manual.
Ê
"Switching on the server" on page 58
Ê
"Enabling BitLocker functionality" on page 83
15.4.2 Removing the TPM
V
CAUTION!
Advise your contact persons that they must provide you with TPM
backup copies. For security reasons, the TPM must be restored/re-
saved by the customer. After installing a new system board, the TPM
must be enabled. You may not clear the TPM data.
If the contact persons
DO NOT
have a backup copy available, inform
them that removing the TPM will cause to lose all data.
15.4.2.1 Preliminary steps
Before removing the TPM, perform the following steps.
Ê
Before removing the TPM board, it is necessary to remove BitLocker-
protection from the computer and to decrypt the volume.
Field Replaceable Unit
(FRU)
Hardware: 30 minutes
Tools:
Removing the system board:
– Phillips PH2 / (+) No. 2 screw driver
Removing the TPM:
– Bit screw driver
– TPM bit insert
(
*
)
(
*
)
For the Japanese market:
– TPM module fixing tool (S26361-F3552-L909)
Summary of Contents for PRIMERGY RX200 S8
Page 30: ...30 Upgrade and Maintenance Manual RX200 S8 Before you start ...
Page 42: ...42 Upgrade and Maintenance Manual RX200 S8 Important information ...
Page 106: ...106 Upgrade and Maintenance Manual RX200 S8 Power supply ...
Page 130: ...130 Upgrade and Maintenance Manual RX200 S8 Hard disk drives solid state drives ...
Page 194: ...194 Upgrade and Maintenance Manual RX200 S8 Expansion cards and backup units ...
Page 210: ...210 Upgrade and Maintenance Manual RX200 S8 Main memory ...
Page 234: ...234 Upgrade and Maintenance Manual RX200 S8 Processors ...
Page 244: ...244 Upgrade and Maintenance Manual RX200 S8 Optical disk drive ...
Page 320: ...320 Upgrade and Maintenance Manual RX200 S8 Cables ...